AG02
Commissioning English
AG02 · Date
31.10.2012 · Art.
No.
82270 · Mod.
status
354/12
51
right
left
fast/creep
right motion-
left motion-
fast/creep motion-
Fig. 14: Input circuit/digital inputs
Display
LED
Digital
Analog unipolar
Analog bipolar
1, yellow blinking 600 ms =
Start Up
blinking 300 ms =
Current
error, On = opera-
tion
2, blue
right
enable
enable
3, blue
left
right/left
N. C.
4, yellow fast/creep
N. C.
N. C.
5.3 Potentiometer setting (P10)
Sense of rotation
The measuring range is a result of the transmission of potentiometer's
gear. We deliver the potentiometer with the left turning direction (see
).To check the sense of rotation take a measurement of the resistance
value between 'Po' and 'S'.
R = 0 Ohm:
sense of rotation i
R = max. value:
sense of rotation e
When correctly connected and switched on, the unit displays show the cur-
rent actual value.
5.4 Setting and alignment of the R/I transformer (MWI)
Sensor of rotation
Ex works, the instrument transformer is aligned to default values: 4 mA for
the start position (Po) and 20 mA for the end position (Pe) of the potenti-
ometer. To check the sense of rotation take a measurement of the current
value between 'I+' and 'I-'.
Current I = 4 mA:
sense of rotation e
Current I = 20 mA: sense of rotation i
NOTICE
NOTICE