EtherHaul™ 8000 Installation, Operation and Maintenance Manual
Page 60
By default, none of the alarms are masked but the RSSI, CINR and Lowest
Modulation threshold-crossing alarms. In addition, some alarms have configurable
thresholds to raise and clear alarm.
This section allows configuring the following parameters:
Event – the event/group of events to be configured
Trap – checkbox to enable sending SNMP trap for this event.
Alarm – checkbox to enable raising an alarm for this event (meaning, showing it
in the active Alarms list and in the log file). Note that not all events can be
configured as Alarms.
Threshold – the following events have configurable thresholds for alarm
raise/clear and for sending traps. The threshold hysteresis can be defined (to
avoid toggling alarms).
o
Temperature – when system temperature exceeds the High or Low
thresholds. Note that system temperature is typically 15-25
°C higher then
ambient temperature.
Refer to the Alarms section under Diagnostics chapter of this manual for detailed
description of the system’s alarms.
6.5
CLI Commands
View system settings:
Show system
Restoring factory default configuration:
clear startup-configuration
reset system
Viewing the startup configuration
copy startup-configuration display
Viewing the currently running configuration
copy running-configuration display
Loading new startup configuration (for example, using FTP):
copy ftp://<ftp_user>:<ftp_password>@<ftp_server_ip>/startup-
configuration.txt flash:startup-configuration.txt
Downloading SW (for example, using FTP):
copy sw ftp://<ftp_user>:<ftp_password>@<ftp_server_ip>/<sw_file_name>