EtherHaul™ 8000 Installation, Operation and Maintenance Manual
Page 46
Note that it will take the ODU to stabilize after loopback up to 3 minutes so set the
loopback timeout accordingly (recommended 600 seconds).
Mute remote transmitter first to avoid interference with the loopback operation.
Refer to the Diagnostics chapter of this manual for detailed description of the
system’s loopbacks.
Mute – checkbox to mute the transmitter with timeout in seconds. When
muted, the ODU will not transmit.
4.4
Modulation Table
Figure 4-5 Radio Page: Modulation Table
The modulation table presents the available modulation profiles. The radio can be
configured only to one of the profiles available in the table.
CINR Low – Lower threshold for stepping down in modulation profile (Adaptive
Mode).
CINR High – Upper threshold for stepping up in modulation profile (Adaptive
Mode).
Note that different modulation tables may apply according to product used.
The modulation profiles and thresholds are optimized and cannot be modified.
Note:
Loopback is performed with MAC addresses swap (swapping DA and SA) for the
address specified only. All other MAC addresses not looped.