1.1.1 Reed contact - Switching of inductive or capacitive loads
CAUTION! Destruction or damage of reed contact!
Take notice of the max. contact loads mentioned on the specification plate!
The max. contact loads mentioned on the type plate (switching voltage, switching current and
switching capacity) refer to pure ohmic loads and may not be exceeded under any circum-
stances.
High voltage and current peaks can occur, particularly when switching inductive or capacitive
loads (e.g. relay coil, capacitors). Even if the overload is brief, this can destroy (welding the
contacts) or damage (reduced lifespan) the reed contact.
Only use protection methods which be appropriate and checked.
Protection method when electrical connection of reed contacts:
The following protective circuits are basically possible: current limiting resistors, RC cir-
cuits, freewheeling diodes, suppression diodes, varistors or a combination of these.
Please verify the effectiveness of the chosen protection method in accordance with the
specific loads involved.
1.2 Exclusion of liability
We accept no liability for any damage or malfunctions resulting from incorrect installation, in-
appropriate use of the device or failure to follow the instructions in this operating manual.
2 Safety
instructions
Before you install the VM100, read through this operating manual carefully. If the instruc-
tions contained within it are not followed, in particular the safety guidelines, this could re-
sult in danger for people, the environment, and the device and the system it is connected
to.
The VM100 correspond to the state-of-the-art technology. This concerns the accuracy, the
operating mode and the safe operation of the device.
In order to guarantee that the device operates safely, the operator must act competently and
be conscious of safety issues.
SIKA provides support for the use of its products either personally or via relevant literature.
The customer verifies that our product is fit for purpose based on our technical information.
The customer performs customer- and application-specific tests to ensure that the product is
suitable for the intended use. With this verification all hazards and risks are transferred to our
customers; our warranty is not valid.