TU 7052 

Connections and functions 

- 4 - 

 

© SIKA 

 Ba TU7052_en 

 08/2009 (03/2019) 

SIKA provides support for the use of its products either personally or via relevant literature. The 

customer verifies that our product is fit for purpose based on our technical information. With this 

verification all hazards and risks are transferred to our customers; our warranty is not valid. 

Qualified personnel: 

 

The personnel who are charged for the installation, operation and maintenance of TU 7052 hold 

a relevant qualification.  

This can be based on training or relevant tuition. The personnel must be aware of this operating 

manual and have access to it at all times. 

 

The electrical connection should only be carried out by a fully qualified electrician. 

General safety instructions: 

 

In all work, the existing national regulations for accident prevention and safety in the workplace 

must be complied with. Any internal regulations of the operator must also be complied with, 

even if these are not mentioned in this manual. 

 

Degree of protection IP20:  

The device is not intended for outdoor use or for use in damp conditions. 

Special safety instructions: 

Warnings that are specifically relevant to individual operating procedures or activities can be found 

at the beginning of the relevant sections of this operating manual. 
  

3  Connections and functions 

Connections:  

: Sensor NPN / PNP connection. 

: Inductive sensor connection. 

: Output circuit connection. 

: Supply voltage connection. 

Function: 

The frequency signal at the input of TU 7052 is divided by the set val-

ue of the divider and provided at the outputs as a square-wave pulse 

signal.  
The output frequency is calculated at follows: 

Divider

frequency

Input 

 

  

frequency

Output 

=

 

With a corresponding circuit, the NPN/PNP output and the optocou-

pler output can be used simultaneously.  
 

4  Installation and electrical connection 

Prior to installation and electrical connection: 

  Switch off the system. 

  Make sure that the system is isolated from all possible sources of supply and is completely de-

energised. 

 

Содержание TU 7052

Страница 1: ...g manual 2 1 Device description 3 1 1 Intended use 3 2 Safety instructions 3 3 Connections and functions 4 4 Installation and electrical connection 4 4 1 Rail mounting 5 4 2 Electrical connection 5 5...

Страница 2: ...dangers that cause personal injuries that can lead to health defects or cause con siderable damage to property CAUTION Material damage This sign indicates actions which could lead to possible damage t...

Страница 3: ...side of the plastic casing of TU 7052 1 1 Intended use The frequency divider TU 7052 should only be used to divide the frequency signals of SIKA flow or volumetric sensors The suitability of other se...

Страница 4: ...s of the operator must also be complied with even if these are not mentioned in this manual Degree of protection IP20 The device is not intended for outdoor use or for use in damp conditions Special s...

Страница 5: ...4 2 1 Flow or volumetric sensor connection All SIKA flow or volumetric sensors can be connected to TU 7052 CAUTION Material damage Malfunctioning and damage may occur if several sensors are connected...

Страница 6: ...cted via terminal 12 and termi nal 11 respectively 4 2 2 2 Optocoupler output The optocoupler of TU 7052 has a direct open collector output which can be connected as either a NPN or PNP output CAUTION...

Страница 7: ...gh the connected flow or volumetric sensor the frequency of the input signal is divided by the set value of the divider The lower square wave pulse signal ap pears at the outputs 7 Maintenance decommi...

Страница 8: ...division range 1 1 1 999 can be set via rotary switches Type of signal Square wave signal duty cycle 1 1 NPN PNP output short circuit proof Signal current Max 20 mA limited current Optocoupler output...

Отзывы: