SIIG AV-GM07L3-S1 Скачать руководство пользователя страница 1

 

 

 
 

 

 
 
 

16x16 HDBaseT-Lite Matrix with POC & 4K2K 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

P/N: AV-GM07L3-S1 

Содержание AV-GM07L3-S1

Страница 1: ...16x16 HDBaseT Lite Matrix with POC 4K2K P N AV GM07L3 S1...

Страница 2: ...unit yourself except where explained in this manual Provide proper ventilation and air circulation and do not use near water Keep objects that might damage the device and assure that the placement of...

Страница 3: ...an power both units from TX side with power supply HDCP 1 4 compliant Bi directional IR pass though Allows controlling local HDMI sources or display through control path Allows to control main matrix...

Страница 4: ...DMI source control Controllable via IR pass through from IR receiver at RX to IR blaster at TX IR remote control Electro optical characteristics 25 Carrier frequency 20 60kHz HDMI connector Type A 19...

Страница 5: ...n Rear Panel 7 IR Blaster 1 16 3 5mm IR blaster socket for individual HDMI source control 8 IR Receiver 1 16 Infrared 3 5mm socket for plugging in the extension cable of IR receiver 9 INPUT 1 16 HDMI...

Страница 6: ...LED light always shine HDCP LED HDCP OFF the LED light is blinking 2 Latch locking power jack Connect to 12V DC power supply 3 RJ 45 Plug in a Cat 5 5e 6 cable that needs to be linked to the receivin...

Страница 7: ...IR Receives IR commands from remote control IR RECEIVER 1 16 Receives IR commands from individual remote control CV 57VA RX IR BLASTER IR control on individual display device IR RECEIVER IR receiver c...

Страница 8: ...DIAGRAM You can buy any IR extension cables in the market that are compatible to the definition of the IR sockets for the matrix if necessary for replacement use However IR cables longer than 2m 6 ft...

Страница 9: ...on the matrix switcher OFF Standby mode PRESET Preset mapping mode SAVE Save current mapping mode Number button 1 9 Select a number 10 Select a number To Transfer key TAKE Trigger the previous setting...

Страница 10: ...8 F4 Reserved...

Страница 11: ...o select All Output A 3 5 Press TAKE button 4 3 Factory Reset Status Status Status Take 1 Press STATUS button 2 Press STATUS button d 3 Press STATUS button d d 4 Press TAKE button 1 1 Learn default ED...

Страница 12: ...10 D 4 Press ALL to select All Input 2 A 5 Press TAKE button 0 F 0 success F fail...

Страница 13: ...Input All 1 Press Learn button E L 2 Press number key 2 to select Output 2 L 3 Press To button 2 L 4 Press ALL to select All Input 2 A 5 Press TAKE button 0 F 0 success F fail Save Current Mapping Sa...

Страница 14: ...00 3 Software size 3 MB 4 Minimum RAM requirement 256 MB 1 I O Routing Button 2 Rename I O Button 3 EDID Button 4 Network Button 5 F W Update Default Reset Button 6 Refresh COM Port 7 COM Port Selecti...

Страница 15: ...Routing Button I O Select the input Save Mapping Select Mapping 1 8 Click Save button to save current mapping Preset Mapping Select Mapping 1 8 Click Recall button to recall previous mapping which ar...

Страница 16: ...14 2 Rename I O Button Rename I O Rename output name Rename input name Rename Mapping Rename Mapping name...

Страница 17: ...Dolby 5 1ch 2 Full HD 1080p 60 24bit 2D 7 1ch 3 Full HD 1080p 60 24bit 3D 2ch 4 Full HD 1080p 60 24bit 3D 7 1ch 5 HD 1080i 60 720p 60 24bit 2D 2ch 6 HD 1080i 60 720p 60 24bit 2D 7 1ch 7 Full HD 1080p...

Страница 18: ...utput Select Input Click Learn button to learn display EDID Load EDID File to Input Select Input Click Load button to select the EDID file View EDID Select Input or HDMI output Click View button to re...

Страница 19: ...17 Select the EDID content Click Save EDID on Computer to save the generated EDID as a file 4 Network Button...

Страница 20: ...18 Save Setting Save the IP address which you key in on the column Read Setting Read the IP address from the device PS The default IP address is 192 168 1 111...

Страница 21: ...mware version information Factory Reset To do factory default reset Help To view the steps of the firmware update Firmware Update Main Board Firmware Update Valens Firmware Update DB Board Firmware Up...

Страница 22: ...t Disconnect Button Click this button to change connection status 10 RS 232 Button Click button to switch to RS 232 function If RS 232 is connected the button will show the sign image to let you know...

Страница 23: ...Web Interface Control The default IP address 192 168 1 111 Account admin Password matrix 1 I O Routing Button 2 Setting Button 3 EDID Button 4 Refresh I O Status Read I O Name Button 1 I O Routing But...

Страница 24: ...Select the input Save Mapping Select Mapping 1 8 Click Save button to save current mapping Recall Mapping Select Mapping 1 8 Click Recall button to recall previous mapping which are saved 2 Setting B...

Страница 25: ...Rename I O Rename output name Rename input name Rename Mapping Rename Mapping name Password change the password has to be 6 characters Key in old password Key in new password Key in new password agai...

Страница 26: ...1080p 60 24bit 3D 7 1ch 5 HD 1080i 60 720p 60 24bit 2D 2ch 6 HD 1080i 60 720p 60 24bit 2D 7 1ch 7 Full HD 1080p 60 36bit 2D 2ch 8 Full HD 1080p 60 36bit 2D 7 1ch 9 4K2K 30Hz 24 Bit 7 1ch 10 4K2K 30Hz...

Страница 27: ...DMI display among others to make sure all displays are capable to play the HDMI signals normally There are THREE methods to do EDID Learning as below 1 Front Panel Push in Button Please refer to the O...

Страница 28: ...in transit Under no circumstances will a unit be accepted without a return authorization number The warranty is in lieu of all other warranties expressed or implied including without limitations any...

Отзывы: