THIS GUIDE IS ONLY FOR SUITABLY SKILLED AND EXPERIENCED INSTALLERS OF EMERGENCY VOICE COMMUNICATION SYSTEMS (EVCS)

 and summarises key information provided in the 

full manual (Document No. DAU0000091). Section numbers, e.g.          , reference sections in the full manual with additional information.

SigTEL (1 to 16 Lines) Standalone EVCS - Quick Start Installation Guide

FUSE

16 x

extensions

EVC302F

EVC301RPO

EVC302

GS

3A fuse

d

 spur

Outstation lines:

 2-

c

ore 

 

enhan

c

e

d

 

fire rate

d

 

c

a

b

le (1.0 to 1.5 mm

2

)

, up 

to 1 km in len

g

th.

Power supply:

 Fixe

d

 wirin

g

, 2-

c

ore 

enhan

c

e

d

 fire rate

d

 

c

a

b

le (0.75 mm

2

 

to 2.5 mm

2

) fe

d

 from a swit

c

he

d

 spur, 

fuse

d

 at 3 amps.

NC951

NC951 lines:

 2-

c

ore 

c

a

b

le.

ECU-16 (shown) has
16 availa

b

le extensions.

ECU-8 has ei

g

ht an

d

 

ECU-4 has four.

ECU-16
Controller

1

2

4

3

1 of 2

Approved Document No. DAU0000093 Rev 3

SigTEL

 

Emergency Voice 

C

ommunication System

SigTEL EVCS Typical Wiring Overview

Install the EVCS

 

 
Location 

Site all equipment indoors in well-lit areas, free from obstruction. Site controllers in the control room or lobby, 1.4 
metres above final floor level (FFL). Fit Type A (fire telephone) outstations in fire fighting lobbies and fire access points, 
1.3 to 1.4 metres above FFL. Fit Type B (disabled refuge) outstations in disabled refuges, 0.9 to 1.0 metre above FFL. 

 

Mounting 

Remove ba

s

e PCB

s

 before fir

s

t fix in

s

tallation

 to protect them and expose the base mounting holes. Wall mount the 

controllers, either surface or semi-flush. Fix the base securely onto a wall using No.8 round-head, or countersunk 
screws. After mounting, remove any dust/swarf and re-install base P

C

Bs. Ensure all connecting looms are refitted.

6

.1

6

.1

Wiring 

See Fig 1 above for cable types. Install wiring in accordance with the relevant national, regional or local regulations (in the UK this is the IEE 
Wiring Regs BS 7

6

71 and BS 5839 Part 1. Use enhanced fire-rated cables from the controlller to the Type A & B outstations and the power supply. 

 

Te

s

t Exten

s

ion

s

 

Test all extensions for faults before terminating to the controller using a FITT EV

C

 line tester (see component list above). 

CAUTION: DO NOT u

s

e an In

s

ulation Re

s

i

s

tance Te

s

ter with any device

s

 connected a

s

 they will be de

s

troyed and the warranty will be void. 

 

Fit Out

s

tation

s

 & NC95

1

 Interface 

Maximum recommended cable distance to the outstations is 1 km, beyond which audio quality may degrade. For wiring and connection 
details refer to Type A outstation instructions (Doc. No. D

C

M0003819) and Type B outstation instructions (Doc. No. DAU0302000).

 

 

Connect Exten

s

ion

s

 to the Controller 

Do not connect extensions to the controller until they have been tested, fault-free and suitable cable glands fitted. 

C

onnect extensions 

directly to the Master Exchange P

C

B inside the controller (see Fig 2 left). 

C

onnect screens to the earth terminal in the back of the enclosure.

8 x Extensions from Outstations 

&

 NC951

 

16 x Extensions from Outstations 

&

 NC951

L1    L2

 

+  -   +  - 

L3    L4

 

+  -   +  - 

L5    L6

 

+  -   +  - 

L7    L8

 

+  -   +  - 

N/O C N/C 0V +24 OP3 OP2 OP1

 

I/P A   I/P B   I/P C 

+  -   +  -   +  -  

All s

c

reens 

c

onne

c

t

to Earth terminal

ECU-16

Master Ex

c

hange PCB

C D

B

L9    L10

 

+  -   +  - 

L11  L12

 

+  -   +  - 

L13  L14

 

+  -   +  - 

L15  L16

 

+  -   +  - 

C

L1    L2

 

+  -   +  - 

L3    L4

 

+  -   +  - 

L5    L6

 

+  -   +  - 

L7    L8

 

+  -   +  - 

N/O C N/C 0V +24 OP3 OP2 OP1

 

I/P A   I/P B   I/P C 

+  -   +  -   +  -  

All s

c

reens 

c

onne

c

t

to Earth terminal

ECU-8 or ECU-8NT

Master Ex

c

hange PCB

B

C

Fig 2

7

4

11

13.1

SigTEL EVCS Component

s

12

Fig 1

Part No.

De

s

cription

E

C

U-4

4 Line Master EV

C

 

C

ontroller c/w handset & display, requires two 12

 

V 7

 

Ah batteries

E

C

U-8

8 Line Master EV

C

 

C

ontroller c/w handset & display, requires two 12

 

V 7

 

Ah batteries

E

C

U-1

6

1

6

 Line Master EV

C

 

C

ontroller c/w handset & display, requires two 12

 

V 7

 

Ah batteries

E

C

U-8NT

8 Line Master EV

C

 

C

ontroller (no handset) c/w display, requires two 12

 

V 7

 

Ah batteries

EV

C

302F/GF

Disabled Refuge (Type B) Outstation, flush mounting, stainless steel (‘G’ - Green fascia)

EV

C

302S/GS

Disabled Refuge (Type B) Outstation, surface mounting, stainless steel (‘G’ - Green fascia)

EV

C

301RPO

Red Fire Telephone (Type A) Outstation c/w handset (push to open)

EV

C

301RLK

Red Fire Telephone (Type A) Outstation c/w handset (lift lock)

BF359/1

Weatherproof enclosure for EV

C

302F/GF

BF359/3D

Stainless steel enclosure for controller (E

C

U-4 / E

C

U-8 / E

C

U-1

6

)

N

C

951

Disabled Persons Toilet Alarm (DPTA)

FITT

EV

C

 Line Tester

B

C

28

6

/2

24 V 7 Ah battery (2 x 12 V) used with controller (E

C

U-4 / E

C

U-8 / E

C

U-1

6

 / E

C

U-8NT)

AFP385

Grey flush bezel for controller (E

C

U-4 / E

C

U-8 / E

C

U-1

6

 / E

C

U-8NT)

T-BEZ301

Red flush bezel for EV

C

301RPO and EV

C

301RLK

E

C

U423

P

C

 programming software

Отзывы: