background image

Page  1  of  4 

DocNo.DCP0001330  RnB  25/02/04  rev2 

 

Operation Instruction Manua

1ZDM

   

Single Zone Desk Microphone

 

 

Features 

 

 

The 1ZDM has compressor, noise gate, equalisation 
controls and optional chime (one to three note). 
The unit is fully monitored and complies with BS5839 part4. 
Simple operation by the use of a single button Speak bar. 
The unit is supplied in a sturdy plastic desk mounting case 
with a gooseneck microphone fitted. 

Technical Description 

Microphone signals are passed to a voltage controlled 
amplifier under control of a signal derived from rectifying 
the stage output signals, providing 3:1 compression ratio. 
The output of this stage is fed to an LED output level 
display and a three-band equaliser (100 Hz, 1KHz, 10 kHz). 
Power is supplied at nominal 24 VDC via separate cabling, 
the phantom power on the audio + and audio - being used 
for fault detection only.  A regulator circuit provides 15 VDC 
for powering the 1ZDM electronics. 

Front Panel Features 

The 1ZDM provides for the following LED indications

:

 

 

 

Name 

Function / Description 

OK 

GREEN when no fault detected. 

FAULT 

AMBER when fault detected. 

SPEAK 

GREEN when system ready for paging announcement, FLASHING GREEN when system is 
busy. 

VU 

VU meter to show audio level.  VU meter is constantly active and will light in sync with audio 
peaks to indicate that the audio path to the input stage is intact.  This occurs even when speak 
bar is not pressed. 

Block Diagram 

 

 

Отзывы: