Chapter 6
| Remote Monitoring Commands
– 185 –
show rmon history
This command shows the sampling parameters configured for each entry in
the history group.
Command Mode
Privileged Exec
Example
Console#show rmon history
Entry 1 is valid, and owned by
Monitors 1.3.6.1.2.1.2.2.1.1.1 every 1800 seconds
Requested # of time intervals, ie buckets, is 8
Granted # of time intervals, ie buckets, is 8
Sample # 1 began measuring at 00:00:01
Received 77671 octets, 1077 packets,
61 broadcast and 978 multicast packets,
0 undersized and 0 oversized packets,
0 fragments and 0 jabbers packets,
0 CRC alignment errors and 0 collisions.
# of dropped packet events is 0
Network utilization is estimated at 0
.
.
.
show rmon statistics
This command shows the information collected for all configured entries in the
statistics group.
Command Mode
Privileged Exec
Example
Console#show rmon statistics
Interface 1 is valid, and owned by
Monitors 1.3.6.1.2.1.2.2.1.1.1 which has
Received 164289 octets, 2372 packets,
120 broadcast and 2211 multicast packets,
0 undersized and 0 oversized packets,
0 fragments and 0 jabbers,
0 CRC alignment errors and 0 collisions.
# of dropped packet events (due to lack of resources): 0
# of packets received of length (in octets):
64: 2245, 65-127: 87, 128-255: 31,
256-511: 5, 512-1023: 2, 1024-1518: 2
.
.
.
Содержание SC30010
Страница 1: ...C 300 Series Gigabit Managed Switch CLI Reference Guide SOFTWARE RELEASE V1 1 10 171 www signamax com ...
Страница 2: ...CLI Reference Guide SC30010 C 300 48 Port Gigabit Managed Switch E122017 KS R01 ...
Страница 482: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 482 ...
Страница 670: ......
Страница 671: ...E122017 KS R01 ...