Chapter 4
| System Management Commands
Time Range
– 145 –
Command Usage
Note that when SNTP is enabled, the system clock cannot be manually
configured.
Example
This example shows how to set the system clock to 15:12:34, February 1st,
2015.
Console#calendar set 15:12:34 1 February 2015
Console#
show calendar
This command displays the system clock.
Default Setting
None
Command Mode
Normal Exec, Privileged Exec
Example
Console#show calendar
Current Time : May 13 14:08:18 2014
Time Zone : UTC, 08:00
Summer Time : Not configured
Summer Time in Effect : No
Console#
Time Range
This section describes the commands used to sets a time range for use by
other functions, such as Access Control Lists.
Table 25: Time Range Commands
Command
Function
Mode
Specifies the name of a time range, and enters time
range configuration mode
GC
Sets the absolute time range for the execution of a
command
TR
Sets the time range for the periodic execution of a
command
TR
Shows configured time ranges.
PE