Страница 1: ...Signamax Connectivity Systems OAM Managed Dual Rate Converter Series U S E R S G U I D E ...

Страница 2: ...Signamax Connectivity Systems OAM Managed Dual Rate Converter Series User s Guide ...

Страница 3: ...ntial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Signamax Connectivity Systems from Advanced Electronic Supports Products Inc All rights...

Страница 4: ...ed Dual Rate Media Converter introduced here provides one channel media conversion solution 10 100 1000BaseTX to 100Base or 1000Base dual rate fiber interface The Signamax OAM Managed Dual Rate Media Converter fully complies with IEEE802 3 10BaseT IEEE802 3u 100BaseTX FX IEEE802 3ab 1000BaseT and IEEE802 3z 1000BaseSX LX Ethernet standards In this manual you will find Product overview Features on ...

Страница 5: ...DUCT FEATURES 4 PACKING LIST 4 ONE CHANNEL MEDIA CONVERTER 6 PORTS 6 FRONT PANEL LEDS 6 RESET BUTTON 7 INSTALLATION 8 SELECTING A SITE FOR THE EQUIPMENT 8 CONNECTING TO POWER 8 INSTALLING IN A CHASSIS 8 SYSTEM CONFIGURATION 10 LOGGING ON TO THE MEDIA CONVERTER 10 MAIN MENU 11 NETWORK INFORMATION 12 LOCAL SETTING 13 REMOTE SETTING 27 TOOLS 31 LOGOUT 34 SPECIFICATIONS 35 CONTACT INFORMATION 36 ...

Страница 6: ...ostic One fiber interface supports dual rate 100BaseFX BX or 1000BaseSX LX BX fiber transmission Gigabit transmission supports 9K Bytes jumbo frame 1000Mbps Auto Full duplex 10 100Mbps Full Half duplex Auto Negotiation Auto MDI MDIX Supports IEEE802 3x Flow control Flow control for Full duplex and Back pressure for Half duplex Full wire speed forwarding rate Operating voltage and Max current consu...

Страница 7: ...Signamax OAM Managed Dual Rate Media Converter User s Manual 5 The Media Converter User s Manual AC to DC Power Adaptor ...

Страница 8: ...ady Power On PWR stands for Power Off Power Off Copper Port Speed Steady Green Copper Port connection at the speed of 1000Mbps Amber Copper Port connection at the speed of 100Mbps Off Copper Port connection at the speed of 10Mbps LNKC Green Steady A valid network connection is established on FX port Flashing Data transmitting OAM LOOP Green Steady When device in OAM Active Mode Flashing Blinks for...

Страница 9: ... or a similar object into the reset hole to press the reset button Reset the web interface IP to 192 168 1 10 Insert a paper clip or a similar object into the reset hole Press and hold the reset button for 5 10 seconds Reset to factory default Insert a paper clip or a similar object into the reset hole Press and hold the reset button for 10 seconds until the OAM LOOP LED slowly blinks ...

Страница 10: ... IEC 801 3 Level 2 3V M field strength Make sure that the equipment receives adequate ventilation Do not block the ventilation holes on each side of the equipment The power outlet should be within 1 8 meters of the product Connecting to Power This Converter is a plug and play device Connect the supplied AC to DC power adapter to the receptacle at the back of the converter Attach the plug into a st...

Страница 11: ...nverter User s Manual 9 NOTE Never insert any converter into the chassis directly without using the supplied carriers The carriers allow secure and consistent placement of the converters into the chassis backplane without causing any damage ...

Страница 12: ...ation about how to configure the OAM Managed Dual Rate Media Converter via the Web Browser Logging on to the Media Converter The default IP Address for the OAM Managed Media Converter is 192 168 1 10 Enter the factory default Username admin Enter the factory default Password no password Then click on the Login button to log on to the OAM Managed Media Converter ...

Страница 13: ...Signamax OAM Managed Dual Rate Media Converter User s Manual 11 Main Menu ...

Страница 14: ...Signamax OAM Managed Dual Rate Media Converter 12 User s Manual Network Information It will show local device information and local port status ...

Страница 15: ...y self if DHCP Client is disabled The IP Address would be provided by DHCP Server if the DHCP Client is enabled IP Address Click in IP Address text box and type a new address to change the IP Address Subnet Mask Click in Subnet Mask text box and type a new address to change the Subnet Mask Gateway Click in the Gateway text box and type a new address to change the Gateway Description Click in the D...

Страница 16: ...pe the old password You must type the old password into this field if you want to set a new password The password must be a z A Z 0 9 and _ The max length is 16 characters New Password Click in New Password text box and type a new password Confirm Click in Confirm text box and type the new password in Confirm text box again to verify it Apply Click Apply button when you finished Password Setting ...

Страница 17: ... Pass Through Choose Disable or Enable this function to disable or enable Link Fault Signaling Forward CRC Error Frame The CRC error packets will be passed if enable this function Otherwise the CRC error packets will be dropped Forward Pause Frame The media converter will forward pause frame and regard it as a normal packet if enable this function Management Packet High Priority Need to reset medi...

Страница 18: ...arantee bandwidth Broadcast Storm Filter If enable this function when too many broadcast packets arrive in a period time the broadcast packets will be dropped Multicast Storm Filter If enable this function when too many multicast packets arrive in a period time the multicast packets will be dropped Unknown DA Unicast Storm Filter If enable this function when too many unknown DA unicast packets arr...

Страница 19: ...Control drop down list to disable or enable Flow Control for TP or FX port Ingress Rate Limit kbps Click Ingress Rate Limit drop down menu to choose the ingress rate limit from the Ingress Rate Limit drop down list for TP or FX port Or click Ingress Rate Limit drop down menu to choose the User Setting from the Ingress Rate Limit drop down list for TP or FX port Then click in Ingress Rate Limit tex...

Страница 20: ...ose the User Setting from the Egress Rate Limit drop down list for TP or FX port Then click in Egress Rate Limit text box and type an egress rate limit for TP or FX port The egress rate limit should be divided exactly by 64 because 64kbps is as a minimal step for egress rate limit The program will change the egress rate limit to 64 automatically if the egress rate limit is not divided by 64 for ex...

Страница 21: ...ate Media Converter User s Manual 19 MIB Counter This page shows local device s MIB counters Clear All MIB counters will be cleared to zero if click Clear button Refresh Click Refresh button to show the current MIB counters again ...

Страница 22: ...own list to disable or enable SNMP functions Trap Mode Click Trap Mode drop down menu to choose Disable or Enable from the Trap Mode drop down list to disable or enable to send trap event to SNMP server SNMP Trap IP Address Click in SNMP Trap IP Address text box and type SNMP server s IP address used for trap destination IP Apply Click Apply button when you finished SNMP Configuration ...

Страница 23: ...d type a read community name Delete Read Community Click in Delete Read Community text box and type a read community name to be deleted SNMP Write Community Add Write Community Click in Add Write Community text box and type a write community name Delete Write Community Click in Delete Write Community text box and type a write community name to be deleted Clear Read All Click Clear Read All button ...

Страница 24: ...amax OAM Managed Dual Rate Media Converter 22 User s Manual Clear Write All Click Clear Write All button to clear all write community names Apply Click Apply button when you finished SNMP Community Setting ...

Страница 25: ...o choose Disable or Enable from the VLAN Mode drop down list to disable or enable 802 1Q VLAN Group User could set 16 VLAN entries if enable 802 1Q VLAN Group functions Each VLAN entry could set VID and member port The VID should be 1 4094 Apply Click Apply button when you finished VLAN Group setting VLAN Per Port Setting ...

Страница 26: ...d packets and an insertion for untagged packets Remove Tag The media converter will remove VLAN tags from packets if they are tagged when these packets are output The media converter will not modify packets received without tags Add Tag The media converter will add VLAN tags to packets if they are not tagged when these packets are output on this port The media converter will not add tags to packet...

Страница 27: ...anual 25 Don t Touch Tag Do not insert or remove VLAN tags to from packet which is output on this port Port VLAN Entry Select Port based VLAN index The number means VLAN table entry index not VID Apply Click Apply button when you finished VLAN Group setting ...

Страница 28: ...Out Layer VLAN Tag EtherType text box and type user defined Q in Q out layer VLAN tag Ether type Out Layer VLAN VID DEC Click in Out Layer VLAN VID text box and type user defined Q in Q out layer VLAN tag VID Q in Q direction Click Q in Q direction drop down menu to choose P0 Add QinQ Tag P1 Remove Tag or P1 Add QinQ Tag P0 Remove Tag from the Q in Q direction drop down list to select Q in Q direc...

Страница 29: ...sable or Enable to disable or enable 802 3ah function 802 3ah Mode Choose Passive or Active to set passive or active 802 3ah mode Remote Loopback Choose Disable or Enable to disable or enable remote loopback Apply Click Apply button when you finished 802 3ah OAM Configuration Refresh Click Refresh button to show the current 802 3ah status again ...

Страница 30: ...oopback Test Send Packet Number 1 255 Click in Send Packet Number text box and type packet number to be sent Packet Length Not include CRC 60 1514 Click in Packet Length text box and type packet length Apply Click Apply button when you finished 802 3ah Loop Back Test ...

Страница 31: ...Signamax OAM Managed Dual Rate Media Converter User s Manual 29 802 3ah Status ...

Страница 32: ...Signamax OAM Managed Dual Rate Media Converter 30 User s Manual This page shows 802 3ah Status Information of the media converter ...

Страница 33: ...Signamax OAM Managed Dual Rate Media Converter User s Manual 31 Tools System Reboot OK Click OK button to restart the media converter OK Click Cancel button to cancel the media converter restarting ...

Страница 34: ...erter as backup LoadFromFlash Click LoadFromFlash button to restore to previous backup configuration The Web Interface may be disconnected for restoration ResetToFactory Click ResetToFactory button The Web Interface will be disconnected The system will back to factory default mode after media converter resets all configurations The default IP address is 192 168 1 10 ...

Страница 35: ...33 Firmware Upgrade Browse Click Browse button to select the location and file of the new firmware image file on your computer Upgrade Click Upgrade button The new firmware image file will be burned into the flash Reset the media converter to use the new firmware ...

Страница 36: ...Signamax OAM Managed Dual Rate Media Converter 34 User s Manual Logout OK Click OK button to logout of the media converter OK Click Cancel button to cancel the media converter logout ...

Страница 37: ...100 200Mbps for half full duplex 200Mbps for full duplex 2000Mbps for full duplex 2000Mbps for full duplex Forwarding rate 14 880pps for 10Mbps 148 810pps for 100Mbps 1 488 100pps for 1000Mbps LED Indicators Device PWR OAM LOOP Fiber port LNKF GE TX port LNKC Copper Port Speed LFS Dimensions 3 16 W x 4 3 D x 0 94 H 80 3mm W 109 2mm D 23 8mm H Weight 1 1lbs 0 5Kg Power External power adaptor 12VDC ...

Страница 38: ...s Manual Contact Information SIGNAMAX CONNECTIVITY SYSTEMS An AESP Company 999 N W 159th Drive Miami Florida 33169 U S A Phone 305 944 7710 Fax 305 949 4483 Sales 800 446 2377 Tech Support 800 446 2377 ext 201 E mail Http www signamax com info signamax com ...