SIGNAMAX a.s.
Office: Vlarska 22, 627 00 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
29
add<community>
Add a new community in SNMP. The name of
the community is limited to 20 alphanumeric
characters long.
<community>: Enter the community name.
For example:
SWH(snmp-community)# add myswitch
delete<community>
To delete a community that is already added to
the Managed switch.
For example:
SWH(snmp-community)# delete myswitch
exit
Quit SNMP service mode.
SWH(snmp-
community)#
show
Show SNMP service information.
state <enable | disable>
To enable or disable this community.
For example:
SWH(snmp-community_community name)#
state enable
description <description>
Enter a unique description for this community
name of up to 35 alphanumeric characters. This
is used for reference only.
For example:
SWH(snmp-community_community name)#
description rdcommunity
ip <enable | disable>
To enable or disable IP security. If enabled, the
community may access the Managed Switch
only through the management station, which has
the exact IP address specified in IP address
field below. If disabled, the community can
access the Managed Switch through any
management stations.
For example:
SWH(snmp-community_community name)# ip
enable
ip_addr <ip_addr>
Specify the IP address used for IP Security
function.
<ip_addr>: Enter the IP address.
SWH(snmp-
community_
com
munity name
)#
level <administrator |
read_and_write | read_only |
access_denied>
Specify the desired privilege for the SNMP
operation.
<administrator | read_and_write | read_only |
access_denied>: Four operation privileges are
available in the Managed Switch.
Administrator: Full access right includes
maintaining user account & system information,
loading factory settings, etc.
Read & Write: Full access right but cannot
modify user account and upgrade Firmware.
Read Only: Allow to retrieve information only.
Access Denied: Access to the Managed Switch