SIGNAMAX a.s.
Office: Vlarska 22, 627 00 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
115
Ingress Port: Select which port is the ingress port. Select “any” to denote any ports are
ingress ports or select a port number
Frame Type: Select which frame type applies to this rule.
Any: Select “Any” to denote any frame types.
Ethernet: Select “Ethernet” to denote the frame type that conforms to 802.3 Ethernet
standard.
LLC: Specify “LLC” to denote Logical Link Control or SNAP frames (RFC 1042).
Other: Specify “other” to denote other control values except LLC frames.
Source MAC: Select “Any” to denote all MAC addresses or type a specific source MAC
address in AA:AA:AA:AA:AA:AA format.
Destination MAC: Select “Any” to denote all MAC addresses or type a specific destination
MAC address in AA:AA:AA:AA:AA:AA format.
Ether Type: Select “Any” to denote any Ethernet types or specify Ethernet type value in
hexadecimal notation.
VID: Select “Any” to denote traffic from any VLAN or specify an existing VID to denote
source traffic from the specified VLAN.
TCP/UDP Source Port: Select “Any” to denote any TCP/UDP source port numbers apply or
specify a specific source port number between 0 and 65535.
TCP/UDP Destination Port: Select “Any” to denote any TCP/UDP destination port numbers
apply or specify a specific destination port number between 0 and 65535.
TCP Flags: Select “Any” to denote any values in TCP flag field or specify a specific TCP
flag value.
SVID: Select “Any” to denote any service provider VIDs or specify a specific service provider
VID.
IPv4: To enable or disable IPv4 traffic to pass through.
Any: Any IP versions will apply.
Enable: IP must be version 4.
Disable: IP does not have to be version 4.
IPv6: To enable or disable IPv6 traffic to pass through.
Any: Any IP versions will apply.