User‘s Guide
8-Port 10/100/ BaseT/TX +
Model:
065-7707
0
User‘s Manual
Revision A1
Страница 1: ...User s Guide 8 Port 10 100 BaseT TX Model 065 7707 0 User s Manual Revision A1 ...
Страница 2: ...ation Guide 7 3 1 Installation 7 3 1 1 Hardware Installation on the desktop 7 3 1 2 Hardware Installation on the Rack 7 3 1 3 Power Supply 7 3 2 Appearance of the Switch 8 3 2 1 Front panel 8 3 2 2 Back Panel 8 3 3 Notice 9 CHAPTER 4 WEB Management 10 4 1 Summarization 10 4 2 Connection of WEB Management 10 4 2 1 Preparation 10 4 2 2 Connection 14 4 3 WEB Management Interface and Operation 15 4 3 ...
Страница 3: ... of Band Connection 33 5 3 The interface and operating way of TELNET Out of Band 34 5 4 Cli command and assist of use 34 5 4 1 Phrase Help 34 5 4 2 Command Usage Illumination 35 5 4 3 General command 35 CHAPTER 6 Telnet Management 38 6 1 Summarization 38 6 2 Telnet connection method 38 6 3 Connection 40 2 ...
Страница 4: ...ould be in your box One Switch One AC power cable One Serial cable One user s Guide L type Brackets Note If any of the listed contents are damaged or missig please contact the retailer from whom you purchased the Switch for assistance 3 ...
Страница 5: ...111111111111111111111111 This User s Guide tells you how to use 065 7707 management switch 1 2 Overview of this User s Guide1111111111111111111111111111111111 Chapter 1 About the User s Guide Chapter 2 Introduction Describes the switch and its features Chapter 3 Installation Help you to get started with the basic installation of the switch Chapter 4 General conception of Switch Chapter 5 WEB Manag...
Страница 6: ...upport IEEE 802 3x flow control for full duplex mode and collision based backpressre for half duplex mode 065 7707 support 8 10 100M Auto Negotiation RJ45 ports Support RJ 45 port Auto MDI MDIX Provide one DTE equipment configuration serial port Support 8 Port VLAN 256 IEEE 802 1 Q Tag VLAN Support MTU VLAN group Support MAC address binding Support port trunk function Support Port Mirror Support p...
Страница 7: ...ase T UTP category 3 or above 100Base TX UTP category 5 MAC Address table 4K Backboard bandwidth 1 6G Filter and Transfer Rates 10Mbps 14880pps 100Mbps 148800pps 10 100M Link Act LED Indicator Other Power Dimension L W H mm 230 147 44 Environment Operating Temperature 0 40 Operating Humidity 10 90 non condensing Storage Temperature 40 70 Storage Humidity 5 90 non condensing Input Input 180 260VAC ...
Страница 8: ...otective paste on the 4 pads and paste them in the 4 circular slots in the underside of the switch 3 Turn the switch over and put it on the desktop 3 1 2 Hardware Installation on the Rack1111111111111111111111111111111111111 The dimension of the switch is compliant with the EIA Electronic Industries Association standard 19 in rack 1 Fix up the 2 L type Brackets on the two lateral side of the switc...
Страница 9: ...use the Out of band Management You can configure the system information network parameter and security management through CLI 8 10Base T 100Base TX RJ 45 port They support 10Mbps or 100Mbps bandwidth joint equipment and they all support auto negotiation Each port has 2 LED indicators Link Act indicator and Speed indicator Indicators System indicator Indicators are on the left of the panel 1 Link A...
Страница 10: ...the case of the switch when it s working and don t try to open it yourself even when power off 4 If the switch is connected to the workstation server HUB or other switch by UTP cable the UTP cable should be not longer than 100m For 10Base T Ethernet the cable used should be UTP category 3 or above For 100Bas TX Ethernet the cable used should be UTP category 5 or above You can plug in or pull out t...
Страница 11: ...111111111111111111111111111111111111111 The first step in getting started in using Web based management for your Switch is to secure a browser such as Microsoft Internet Explorer Simply called IE Furthermore the browser must support JavaScript Script For the best effect we suggest you to use IE5 0 or above version If you use Netscape browser make sure it is the newest version Before getting start ...
Страница 12: ...ettings If you use Internet Explorer 5 0 make sure to choose Every visit to the page Otherwise it may cause some WebPages indicate the switch configuration information mistakes If you use Internet Explorer 6 0 you can choose Every visit to the page or Automatically we suggest you choose Automatically 11 ...
Страница 13: ...he web page display slowly If you choose this term you can change to Automatically after you finish the switch WEB configuration Otherwise when you visit other web page the web page will display slowly Internet Explorer 6 0 can solve the issue well you can choose Automatically default The Third step Choose Security User defined Figure 4 3 Securities The Forth Step Choose Enable in the Active Scrip...
Страница 14: ...ply or OK If you feel the screen twinkle after you modify the definition Please click advanced button Adjust display refreshing rate in the pop out window We ignore the details here You can configure switch through WEB via previous setting Notice There are some requirements of PC hardware device to set screen definition to 1024X768 For those old PCs you may not configure it this way 13 ...
Страница 15: ...111111111 We suppose the IP address of the Switch is 192 168 1 254 you can input http 192 168 1 254 in the IE to connect the Switch Then press Enter the following screen will exist Figure 4 6 Enter passwords the switch default passwords is admin Press Login enter WEB switch 14 ...
Страница 16: ...es link up grey indicates link down if it shows black slash it means that this port is disabled Figure 4 7 065 7707 WEB HOMEPAGE The main menu is a tree catalog Clink one main menu item and the sub menu item exists and the window shows the configuration web page of the first sub menu item If you want to configure other item clink the item and the window will show the web page When a main menu item...
Страница 17: ...l Port Base Priority ToS Priority 802 1p Priority Priority Remap Notice Modification to switch configuration only will be effective after you click apply button If you want to save the modification to configuration file of switch you need to click save button to make the modification effective and save it to configuration file of switch 4 3 1 System 111111111111111111111111111111111111111111111111...
Страница 18: ...1111111111111111111111111111 Setting show as figure below Figure 4 10 System password configuration z Current Password the password being used by the user z New Password Password that the user is going to use z Password enter the new password again 4 3 1 3 IP Setting 111111111111111111111111111111111111111111111111111111111111111111 Figure 4 11 Ip Setting 4 3 1 4 File Upgrade 111111111111111111111...
Страница 19: ...TP server Upload Configure File download configure file from TFTP server to the switch and upgrade the configuration parameters Notice 1 When download file make sure the TFTP server contains the file used for upgrade 2 And make sure the appointed TFTP server is running 3 When the file is being download using TFTP protocol you cannot break off the operation or else the switch may act abnormally 4 3...
Страница 20: ...notes the port is unusable If the port is disabled the switch will discard the packets from this port Flow Control Enable denotes this function is in use Disable denotes this function is not in use Auto Negotiation You can choose Auto 10M HD 10M Half Duplex 10M FD 10M Full Duplex 100M HD 100M Half Duplex 100M FD 100M Full Duplex Drop Untag Frame when Enable the frame without Tag header will be dro...
Страница 21: ...6 Mirror Setting Mirror Mode there are 2 modes Enable and Disable Capture Port Port used to attain mirror information Mirrored Port Select the port you want to mirror you can select 1 or more Illumination Trunk group member port cannot be the capture port but it can be the mirrored port The capture port and the mirrored port should be in the same VLAN A port cannot be the capture port and mirrored...
Страница 22: ... and only the data send out from this source address is mirrored Ingress Mirror Mac Address If you haven t select All in the Ingress Mirror Mode item you need enter the Mac address you want to mirror Packet Divide enter a number ranged from 0 to 1023 to denote the number of interval packets between two successive sampling For egress mirror Egress Mirror Mode Egress Mirror Mac Address Packet Divide...
Страница 23: ...x AlignErr the number of received frames with frame align error Rx UnderSz the number of received frames under the size of 64 bytes total length Rx OverSz the number of received frames over the size of 1518 bytes total length Rx Fragmt the number of received fragmentation frame check error under the size of 64 bytes Rx Jabber the number of received Jabber Frames frame check error over the size of ...
Страница 24: ... 10 or 100 Unit Mbps If the port is not linked it shows Duplex Mode it shows Full full duplex or Half half duplex Flow Control Enable indicates the flow control function is in use Disable indicates the flow control function is not used 4 3 2 7 Port Rate 111111111111111111111111111111111111111111111111111111111111111111 Figure 4 22 Bandwith of the Port setting part of the port Ingress Control Enabl...
Страница 25: ...ect the rate then press Change all the port rates of the ports that are enabled the control function will be changed All changes will come effective only after you press Apply or Save You cannot set port rate control for ports in the Trunk group 4 3 2 8 Storm Control 11111111111111111111111111111111111111111111111111111111111111 Fig 4 23 Broadcast Storm Control part of ports Multicast Storm Contro...
Страница 26: ... t been used during the max aging period 2 Max Aging time is 0 to 1 000 000 seconds Overlong will lead switch s improper filter forward due to dynamic MAC address is overtime If too short the addresses will refresh too frequently and many packets will not be correctly located in the Mac addresses the switch will broadcast the data to all ports thus decrease the switch perfromace 3 Both Static Mac ...
Страница 27: ...n be set in all the ports and the max bound MAC address can be up to 416 pieces The bound address is divided into groups according to ports Select the port NO the page will show the bound address of this port Enter the MAC address in the Mac column and press Add or Delete to add or delete Figure 4 26 MAC Binding Number Show the table position of the address Port the corresponding port of the MAC a...
Страница 28: ...111111111111111111111111 VLAN setting is different when the switch is in different VLAN mode In IEEE802 1 Q Tag VLAN mode the setting is as the following Fig4 29 VLAN Setting in IEEE802 1 Q VLAN mode Tag VLAN No VLAN number non reduplicate for the administrator to mark the VLAN Tag VLAN ID VLAN mark non reduplicate Status you can select Enable Disable or Delete Property Untag denotes the port belo...
Страница 29: ...n with one of the other 7ports and create 7 VLANs each of the VLAN includes two ports the Uplink Port and one of the other 7 ports In IEEE802 1Q Tag VLANmode there will be an extra VLAN contains all the ports You can enter the VLAN management menu and view the VLAN setting Notice After you set MTU VLAN and apply all the VLAN and Trunk you set before will be repealed 4 3 5 Trunk 1111111111111111111...
Страница 30: ...lude Qos Global Port Base Priority Tos Priority 8021 p Priority Priority Remap 4 3 6 1 Qos Global 111111111111111111111111111111111111111111111111111111111111111111 Fig4 32 QoS Global QOS Mode there are 4 options Disable Port Based Priority ToS Priority and 802 1 p Priority 802 1p Priority goes into effect 802 1 Q Tag VLAN mode QoS Algorithm there are 2 options WRR and Preempt WRR When you select ...
Страница 31: ...iority Tag if the switch is in 802 1 Q Tag VLAN and the priority mode is 802 1 p Priority the untagged frames received from this port will be endued with Default Priority Tag value Illumination the transmission ratio of the two priority Low and Highest is 1 8 Bandwidth will be distributed according to the transmission ratio when transmitting 4 3 6 3 ToS Priority 11111111111111111111111111111111111...
Страница 32: ... the transmission ratio when transmitting 4 3 6 4 802 1p Priority 1111111111111111111111111111111111111111111111111111111111111 The setting of this page is based on 802 1 p Priority mode Fig4 35 802 1 p Priority Priority Tag Tag priority of the frames If you enable 802 1 p Priority Remap it denotes the remapped new Tag priority Priority transmission priority there 4 options Low High Higher and Hig...
Страница 33: ... the priority value 0 7 in the Tag field of the received packets New Priority Tag the new priority value set by the user The switch will remap the Tag of the received frames to the new priority set by the user so you can change the priority of local transmission without changing the priority Tag of the frames 32 ...
Страница 34: ... port at the left of the swith s backboard with the PC s cinsole port by the cinsole card Then run the Hyper Terminal Refer to the following figure to configure the Hyper Terminal Figure5 1 Hyper Terminal Configuration You can see The speed of the console port is 57600bpS The data bit is 8 bit There is no parity test and flow control The stop bit is 1 If there is no Hyper Terminal in the system yo...
Страница 35: ... 5 4 Cli command and assist of use 111111111111111111111111111111 5 4 1 Phrase Help 11111111111111111111111111111111111111111111111111 There is help information set at the command list interface If you are not so sure about a command phrase please input the initial words you can remember and then input or space following The command will suggest the possible command list And you can input the comm...
Страница 36: ...11111111 The user can use the help commands to get the help information from the system Operation guide 065 7707 provides an on line help the user can input Anytime to get an on line help For instance Switch help Command List Help commands backup Backup configuration file cls Clear the screen del Del commands help Help commands logout Logout Ping Ping a specified host with IP address reset Reset s...
Страница 37: ... the present dialogue promptly Command format logout For instance Switch logout password 5 4 3 6 Ping command 11111111111111111111111111111111111111111111111111111111 This command is equal to Ping command under DOS Command format Ping A B C D Parameter Illumination A B C D is the target IP address For instance Switch Ping 192 168 1 198 Reply from 192 168 1 198 bytes 32 time 5ms TTL 64 Reply from 1...
Страница 38: ... 255 0 Switch set gw 192 168 1 1 Switch show net Network Configuration MAC address 00 11 22 33 44 55 IP address 192 168 1 254 Subnet Mask 255 255 255 0 5 4 3 9 show command 11111111111111111111111111111111111111111111111111111111 This command is used for list the system information of the switch Command format set pswd Usage guide Show the manufacturer model hardware and software version and date ...
Страница 39: ... 6 2 Telnet connection method 11111111111111111111111111111111 Telnet management needs one terminal PC with TCP IP protocol First connect the 10 100M RJ45 port of the switch and the networking adapter port of the PC with networking cable then setting the adapter to be in the same IP segment Take WINDOWS XP as example Step 1 click the right button on the network neighbor at the desktop choose the p...
Страница 40: ...Fig 6 2 Network connection property Step 3 Double click on Internet Protocol TCP IP and you will see the Internet Protocol TCP IP dialogue as below Fig 6 3 TCP IP Property 39 ...
Страница 41: ...rk connection property dialogue Click OK button And then you can start to configure the switch through Telnet 6 3 Connection 1111111111111111111111111111111111111111111 Click the RUN button at the Start menu on the desktop input cmd in the open dialogue window as below Fig 6 4 RUN Click OK button you can see the following dialogue window Fig 6 5 MS DOS Input Telnet 192 168 1 254 at the dialogue wi...
Страница 42: ...Fig6 6 Telnet Management Interface Illumination Telnet configuration for 065 7707 is similar with Out of band management 41 ...
Страница 43: ...ns may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient...