Signal POWER STATION 4 Скачать руководство пользователя страница 21

Series 4 Operating Manual - Nebula                                                             Issue 1.00 
 

 
 www.signal-group.com  

 

P a g e

 | 21

 

of 26 

 

MI/996 (Previous data cable)  

Relay 

No/Digital IO 

Pin 

Colour 

 

Relay No/Digital IO 

Pin 

Colour 

Pink 

 

18 

18 

Grey 

 

68 

Black 

 

 

51 

Black 

Pink 

 

19 

19 

Grey 

 

67 

Pink 

 

 

50 

Pink 

Pink 

 

20 

20 

Grey 

 

66 

Blue 

 

 

49 

Grey 

Pink 

 

22 

21 

Grey 

 

65 

Green 

 

 

48 

Purple 

Pink 

 

GLB ALB23 (NO) 

22 

Grey 

 

64 

Yellow 

 

GLB ALA23 (Com) 

47 

Blue 

Pink 

 

GLB ALC23 (NC) 

23 

Grey 

 

63 

Orange 

 

GND Power 

46 

Green 

White 

 

+24V Fused Output 

24 

Yellow 

 

62 

Red 

 

TTL Sleep 

45 

Orange 

White 

 

NC 

25 

Grey 

 

61 

Brown 

 

TTL CAL 

44 

Red 

White 

 

GND POWER 

26 

Purple 

 

60 

Black 

 

GND POWER 

43 

Brown 

10 

10 

White 

 

DIO1 

27 

Purple 

 

59 

Pink 

 

DIO9 

42 

Black 

11 

11 

White 

 

DIO2 

28 

Purple 

 

58 

Purple 

 

DIO10 

41 

Green 

12 

12 

White 

 

DIO3 

29 

Purple 

 

57 

Blue 

 

DIO11 

40 

Green 

13 

13 

White 

 

 

30 

Purple 

 

56 

Green 

 

DIO12 

39 

Yellow 

14 

14 

White 

 

DIO5 

31 

Purple 

 

55 

Yellow 

 

DIO13 

38 

Orange 

15 

15 

White 

 

DIO6 

32 

Purple 

 

54 

Orange 

 

DIO14 

37 

Red 

16 

16 

White 

 

DIO7 

33 

Purple 

 

53 

Red 

 

DIO15 

36 

Brown 

17 

17 

Grey 

 

DIO8 

34 

Blue 

 

52 

Brown 

 

DIO16 

35 

Black 

Table 4 : Relay wiring table - Colours refer to Signal output cable MI/996 

 

 

 

Содержание POWER STATION 4

Страница 1: ...www signal group com P a g e 1 of 26 Raising gas analysis to new levels...

Страница 2: ...ording or otherwise without the prior written permission of Signal Group Ltd While we believe that the information and guidance given in this manual is correct all parties must rely upon their own ski...

Страница 3: ...intenance 7 2 4 Competent Personnel 8 3 Quick start 9 4 Introduction 11 5 The Principle of Tunable Diode Laser Spectrometry 12 5 1 Sample System 12 6 Operation 13 6 1 Services 13 6 2 Start 14 6 3 Cont...

Страница 4: ...ignal USB Drive containing Operating Manual S4i installation Optional Datasheet Test Reports Shipping kit containing Signal Part No 9000 396010 2m Mains lead cable Sample filter key MC 318011 9 16 Wre...

Страница 5: ...oup Ltd representative for clarification Follow all warnings cautions and instructions marked on and supplied with the product Inform and educate your personnel in the proper installation operation an...

Страница 6: ...s instrument requires pressurised gases for use Some general safety precautions are outlined below however it is advisable that operators are properly trained in the handling and storage of pressurise...

Страница 7: ...unit Fuses may only be replaced with identical items It is forbidden to use repaired fuses or to bypass fuses Substances hazardous to health may escape from the unit s gas outlets It is advisable to e...

Страница 8: ...It is the responsibility of the operating company to Ensure their staff have adequate training Observe safety regulations Follow this instruction manual Operators must Have been properly trained Have...

Страница 9: ...d see a solid blue LED on the front panel indicating that the unit is in Sleep mode An internal fan may also be audible Your instrument is now powered up and ready for general use The various internal...

Страница 10: ...advisable to leave your instrument on for at least an hour before first calibration to allow the detector to stabilise Further details regarding calibration can be found in Section 6 Including calibr...

Страница 11: ...package provides superior performance across the board Standard NEBULA analysers allow optional Measurement ranges as low as 1ppm NH3 equivalent up to as high as 1 NH3 equivalent Full internal heatin...

Страница 12: ...ption lines of a material in a sample gas Therefore one laser detector will be used to measure one gas with little to no chance of any cross sensitivity with other species in the sample 5 1 Sample Sys...

Страница 13: ...racy under 1ppm CH4 equivalent are required you should use zero grade air or an external air purifier such as Signal s model AS80 air purifier Calibration Gases Only NH3 may be used Signal recommends...

Страница 14: ...ect the included or equivalent power cable to the rear panel IEC power socket ensuring the supply voltage is within the operational limits of the instrument Figure 1 NEBULA rear panel Ensure that the...

Страница 15: ...urand s e g 191 C using a heated sample line obtainable from Signal Group Ltd EXHAUST Connect the exhaust to a well ventilated area ensuring that the connection is free from obstruction that could cau...

Страница 16: ...setup for doing this Figure 3 Nebula Calibration Schematic Signal Group LTD provide an external calibration unit with humidifying capabilities that will aid this process Please contact the Sales team...

Страница 17: ...med with the span gas path selected Calibration Through Sample Port If required the analyser may be configured so that calibration is performed through the SAMPLE port instead of the separate SPAN and...

Страница 18: ...ment range of 5 to 25ppm may be chosen The main benefit of this facility is that it allows for greater resolution on the analogue outputs NOTE Each range uses separate calibration curves and coefficie...

Страница 19: ...act Material Ag Au alloy Rated Carry Current 2 A Max switching voltage 125 VAC 60 VDC Max switching current 1 A Max switching power 62 5 VA 30 W Failure rate reference value 1 mA at 5 VDC P level 60 0...

Страница 20: ...L Sleep 45 Blue Black 8 8 Pink Green NC 25 Green Red 61 Yellow White TTL CAL 44 LightBlue Yellow 9 9 Blue Green GND POWER 26 Green Orange 60 Orange White GND POWER 43 Pink Blue 10 10 Green Yellow DIO1...

Страница 21: ...en 7 7 White 24V Fused Output 24 Yellow 62 Red TTL Sleep 45 Orange 8 8 White NC 25 Grey 61 Brown TTL CAL 44 Red 9 9 White GND POWER 26 Purple 60 Black GND POWER 43 Brown 10 10 White DIO1 27 Purple 59...

Страница 22: ...e and to indicate the range in use For range indication 1V range 1 lowest range 2V range 2 etc The outputs may also be configured by users to provide outputs of internally measured temperatures and pr...

Страница 23: ...ion into the heated manifold and fibres can become detached and block critical sample paths Removal Replacement Before filter removal ensure that the Sample gas line has been shut off using an externa...

Страница 24: ...at you will find useful in your servicing and maintenance schedules Cleaning The preferred cleaning method is to immerse the filter in an ultrasonic bath containing a solution of 1 part Ardrox 6333 to...

Страница 25: ...ve these in house skills contact your local Signal representative who will be pleased to assist you 8 2 Service Manual Full service manuals are normally only issued to distributors and agents However...

Страница 26: ...c connections 14 Figure 3 NEBULA calibration schematic 16 10 Table of Tables Table 1 Document history table 1 Table 2 Quick start setup 9 Table 3 Relay wiring table Colours refer to Signal output cabl...

Отзывы: