Страница 1: ...ainrider Vacuum Tube Dynamic Range Controller OWNER S MANUAL Signal Audio Workshop Abarbanel ST 53 Tel Aviv 66089 Israel P O B 5169 TLV 61051 Office 972 3 6820892 Fax 972 3 6824716 www signal audio co...
Страница 2: ...RMS Detector ________________________ Crest Detector ____________________________ Tips Tricks ____________________________ Installation _________________________ Maintenance Calibration ______________...
Страница 3: ...r is a result of a five year development period and 10 years of researching the dynamic behavior of music and audio signals In an effort to innovate and achieve the Gainrider s outstanding capabilitie...
Страница 4: ...recovery time 7 OUT LEVEL Allows you to amplify the output level in order to makeup for gain loses from compression 8 IN LEVEL This is a variable input attenuator for both sides ranging from 20db to...
Страница 5: ...ously or altering the amount of signal to drive into the Gainrider tubes 2 RELAY MATRIX The passive relay matrix is in charge of functions like BYPASS M S NORM modes Carefully planed to preserve signa...
Страница 6: ...me point after the Ratio amp the signal splits into two paths One is the RMS signal path 4 with functions like ATTACK and RELEASE while the other is the CREST which forms in the COMPARATIVE DETECTOR s...
Страница 7: ...y slower then envelopes rise and fall times This is the classic method of compression used by conventional compressor limiters Areas A and B green are fast transients that are too fast for the RMS mec...
Страница 8: ...other tools Tips Tricks 1 Tuning CREST LEVEL will be done only after the initial RMS ATTACK RECOVERY are tuned according to program material You should always remember that the CREST is a by product o...
Страница 9: ...voltage 2 Always install this unit in a properly grounded environment 3 Do not expose the unit to humidity or dusty environment 4 Do not expose the unit to heat sources and unventilated places Connec...
Страница 10: ...eplacing VCA tube a full calibration procedure must be done VCA balance check and calibration is recommended to be preformed once a year VCA Balance calibration Remove the top cover of the unit Connec...
Страница 11: ...el of channel A on the dbm meter when the T H is fully clockwise versus fully counter clockwise calibrate trimmer P1 Channel A till you get a 18dbm drop of output level when T H is fully counter clock...
Страница 12: ...Gainrider PCB top View 12...
Страница 13: ...0 07 to 2 sec Operating Voltage 230Vac 50Hz 115Vac 60Hz Power consumption 40watts Dimensions H 3 Rack Units W 19 D 13 4 All spec s at RL 600Ohm Info subject to change without prior notice All legal ri...