BUILD-IN TOUCH TERMINAL
TAE 2144
4.6 Environmental Conditions
Storage temperature
-25 ... +85 °C
Environmental temperature
0 ... +50 °C
(1)
Humidity
10-95 %, non-condensing
Installation altitude above sea
level
0-2000 m without derating
> 2000 m up to a maximum of 5000 m with derating of the maximum
environmental temperature by 0.5 °C per 100 m
Operating conditions
pollution degree 2
EMC resistance
(2)
in accordance with EN 61000-6-2 (industrial area)
in accordance with EN 61000-6-1 (living area)
EMC noise emission
(2)
in accordance with EN 61000-6-4 (industrial area)
in accordance with EN 61000-6-3 (living area)
Vibration resistance
EN 60068-2-6
5-200 Hz: amplitude 3.5 mm
transition frequency: 8.42454 Hz
acceleration: 1 g
duration: 10 cycles
cycle: 1 octave/minute
Shock resistance
EN 60068-2-27
15 g (147.15 m/s
2
)
Protection type
(2)
EN 60529
protection through housing
front: IP65
cover: IP20
(not UL-listed)
(1)
The maximum environmental temperature allowed depends on the TP connected. The ambient temperature cannot
exceed any of the permissible values.
(2)
Applies only if the PIM 021 is mounted onto the TP.
09.09.2020
Page 15