SRO 021
S-DIAS SAFETY RELAY OUTPUT MODULE
Page 14
02.12.2019
3.2
Lifespan of the Relay Output Module depending on the Number of
Switching Cycles Per Year
0
2 10
5
4 10
5
6 10
5
8 10
5
0
5
10
15
20
Schaltspiele pro Jahr
V
e
rw
en
dun
gs
ze
it
i
n
Ja
hr
e
n
15. 6
B10D
nop
500 00
nop
Duration of relay output module use
20a
B10D-value of the relay used
780000 switching cycles under rated load
Example calculation:
With 50000 switching cycles per year, the relay output module must
be exchanged after 15.6 years (=);
with 39000
switching cycles per year, the lifespan is 20 years.
B10D
500 00
15. 6
=
O