Страница 1: ...SE 052 S DIAS Splitter Ethernet Technical Manual Date of creation 02 08 2019 Version date 02 08 2019 Article number 20 023 052 E ...

Страница 2: ...erved No part of this work may be reproduced edited using an electronic system duplicated or distributed in any form print photocopy microfilm or in any other process without express permission We reserve the right to make changes in the content without notice SIGMATEK GmbH Co KG is not responsible for technical or printing errors in this handbook and assumes no responsibility for damages that occ...

Страница 3: ...s Tyco Mini I O The S DIAS SE 052 Ethernet splitter connects multiple network segments via 5 ports Incoming data packets to an Ethernet port are distributed to the other ports The splitter module is installed in a double wide S DIAS housing The current is supplied from the top over a 4 pin Phoenix connector ...

Страница 4: ... Symbols Used 5 2 2 Disclaimer 6 2 3 General Safety Guidelines 7 3 Residual Risks 8 3 1 Guidelines 8 3 1 1 EU Declaration of Conformity 8 4 Technical Data 9 4 1 Performance Data 9 4 2 Standard Configuration 9 4 3 Electrical Requirements 9 4 4 Miscellaneous 10 4 5 Environmental Conditions 10 5 Mechanical Dimensions 11 6 ESD Protection 12 7 Connector Layout 13 7 1 Front View 13 ...

Страница 5: ... LEDs 13 7 1 2 Connectors 14 7 2 Top View 14 7 3 Applicable Connectors 15 7 4 Applicable Connector Cables 16 7 5 Label Field 17 8 Shielding 18 9 Strain Relief 19 10 Transport Storage 20 11 Mounting 21 12 Maintenance 23 12 1 Service 23 12 2 Repair 23 13 Disposal 24 ...

Страница 6: ...test technicians General knowledge of automation technology is required Further help and training information as well as the appropriate accessories can be found on our website www sigmatek automation com Our support team is happily available to answer your questions Please see our website for our hotline number and business hours 1 2 Contents of Delivery 1x SE 052 1x opposing connector This docum...

Страница 7: ...y if not avoided Indique un danger possible d un risque moyen de décès ou de graves blessures si les consignes de sécurité ne sont pas respectées CAUTION Identifies a low risk danger which can lead to injury or property damage if not avoided Indique un danger avec un niveau de risque faible des blessures légères ou des dommages matériels si les consignes de sécurité ne sont pas respectées Provides...

Страница 8: ...urrent document can be found on our website If necessary contact our support Subject to technical changes which improve the performance of the devices The following documentation is purely a product description It does not guarantee properties under the warranty Please thoroughly read the corresponding data sheets operating instructions and this system handbook before handling a product SIGMATEK G...

Страница 9: ...its online availability indicated Maintain this manual in readable condition and keep it accessible for reference Operate the unit with devices and accessories approved by SIGMATEK only CAUTION Handle the device with care and do not drop or let fall Prevent foreign bodies and fluids from entering the device The device must not be opened otherwise it could be damaged Manipulez l appareil avec préca...

Страница 10: ...The SE 052 conforms to the following European guidelines 2014 35 EU Low voltage guideline 2014 30 EU Electromagnetic Compatibility EMC guideline 2011 65 EU Restricted use of certain hazardous substances in electrical and electronic equipment RoHS Guideline The EU Conformity Declarations are provided on the SIGMATEK website See Products Downloads or use the search function and the keyword EU Declar...

Страница 11: ...e broadcasts that the high interrupt load could cause a real time runtime error or runtime error By configuring the packet filter Firewall or Router accordingly however it is possible to connect a network with SIGMATEK hardware to a third party network without triggering the error mentioned above 4 3 Electrical Requirements Supply voltage 18 30 V DC UL Class 2 or LVLC 1 Supply current over X6 200 ...

Страница 12: ...densing Installation altitude above sea level 0 2000 m without derating 2000 m with derating of the maximum environment temperature by 0 5 C per 100 m Operating conditions pollution degree 2 EMC resistance in accordance with EN 61000 6 2 industrial area EMC noise generation in accordance with EN 61000 6 4 industrial area Vibration resistance EN 60068 2 6 3 5 mm from 5 8 4 Hz 1 g from 8 4 150 Hz Sh...

Страница 13: ...S DIAS SPLITTER ETHERNET SE 052 02 08 2019 Page 11 5 Mechanical Dimensions ...

Страница 14: ...d by touching the control cabinet or ground terminal Electrostatic loads through clothing and shoes can thereby be dissipated Avant de connecter ou de déconnecter un appareil au SE 052 le potentiel avec masse doit être égalisé en touchant l armoire électrique ou la borne de terre Les charges électrostatiques à travers les vêtements et les chaussures peuvent ainsi être dissipées ...

Страница 15: ... LEDs Run green LIGHTS switch IC running DC OK yellow LIGHTS module is supplied with a voltage 18 V Ethernet Link Active green LIGHTS connection between the two PHYs made BLINKS data is exchanged over the Ethernet bus Ethernet Fulld Col yellow LIGHTS full duplex mode LED does not light half duplex ...

Страница 16: ...SE 052 S DIAS SPLITTER ETHERNET Page 14 02 08 2019 7 1 2 Connectors 7 1 2 1 X1 X5 Ethernet Industrial Mini I O 7 2 Top View Pin Function 1 Tx Rx 2 Tx Rx 3 Rx Tx 4 5 n c 6 Rx Tx 7 8 n c ...

Страница 17: ... welded strands Connections Stripping length sleeve length 10 mm Mating direction parallel to the conductor axis or circuit board Conductor cross section rigid 0 2 1 5 mm2 Conductor cross section flexible 0 2 1 5 mm2 Conductor cross section strands ultrasonically compacted 0 2 1 5 mm2 Conductor cross section AWG kcmil 24 16 Conductor cross section flexible with ferrule without plastic sleeve 0 25 ...

Страница 18: ...drag chain capable 0 5 m 16 911 005 1 m 16 911 010 1 5 m 16 911 015 2 m 16 911 020 3 m 16 911 030 5 m 16 911 050 10 m 16 911 100 20 m 16 911 200 50 m 16 911 500 Industrial Mini I O Type 1 on industrial Mini I O Type 1 drag chain capable 0 5 m 16 912 005 1 m 16 912 010 1 5 m 16 912 015 2 m 16 912 020 3 m 16 912 030 5 m 16 912 050 10 m 16 912 100 20 m 16 912 200 ...

Страница 19: ... SE 052 02 08 2019 Page 17 7 5 Label Field Manufacturer Weidmüller Type MF 10 5 CABUR MC NE WS Article number Weidmüller 1854510000 Compatible printer Weidmüller Type Printjet Advanced 230V Article number Weidmüller 1324380000 ...

Страница 20: ...net or directly before the SE 052 over a large surface cable grommets grounding clamps Noise signals can therefore be prohibited from reaching the electronics and affecting the function To avoid compensating currents from the PE which flow over the shielding the conductors it is recommended that the system components have low Ohm and low impedance connections to one another ...

Страница 21: ...S DIAS SPLITTER ETHERNET SE 052 02 08 2019 Page 19 9 Strain Relief The cable must be mounted close to the module e g using a clamp No mechanical stress can be applied to the connection ...

Страница 22: ...or storage and transport the same values for humidity and vibration as for operation must be maintained CAUTION During transport temperature and humidity fluctuations may occur Ensure that no moisture condenses in or on the device Pendant le transport des fluctuations de température et d humidité peuvent survenir Veillez à ce qu il n y ait pas de condensation d humidité dans ou sur l appareil ...

Страница 23: ...wall of the control cabinet The individual S DIAS modules are mounted on the DIN rail as a block and secured with latches The modules must be mounted horizontally module label up with sufficient clearance between the ventilation slots of the S DIAS module blocks and nearby components and or the control cabinet wall This is necessary for optimal cooling and air circulation so that proper function u...

Страница 24: ...SE 052 S DIAS SPLITTER ETHERNET Page 22 02 08 2019 Recommended minimum distances of the S DIAS modules to the surrounding components or control cabinet wall a b c distances in mm inches ...

Страница 25: ...vice This product was constructed for low maintenance operation 12 2 Repair When sent for repair the panel should be transported in the original packaging if possible Otherwise packaging should be selected that sufficiently protects the product from external mechanical influences Such as cardboard filled with air cushioning In the event of a defect repair send the panel with a detailed error descr...

Страница 26: ...SE 052 S DIAS SPLITTER ETHERNET Page 24 02 08 2019 13 Disposal When disposing of the panel the national electronic scrap regulation must be observed The panel cannot be discarded with domestic waste ...

Страница 27: ...S DIAS SPLITTER ETHERNET SE 052 02 08 2019 Page 25 Documentation Changes Change date Affected page s Chapter Note ...

Страница 28: ...SE 052 S DIAS SPLITTER ETHERNET Page 26 02 08 2019 ...