S-IPC
INTEL
®
ATOM DUAL CORE
21.02.2014 Page
23
o
With the help from the "net stop sipclaunch" command, the alarm mes-
sages are deactivated until the next restart ("Start" – "execute" or the se-
lect input requirement). The service is thereby ended.
o
With „net start sipclaunch“ the service and therewith the alarm messages
are reactivated
o
With the
"HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\
SipcLaunch\Start" registry key
the alarm service can be deactivated :
A value of 2 (= SERVICE_AUTO_START) means that the ser-
vice is started while booting and alarm messages are generated.
A value of 3 (= SERVICE_DEMAND_START) means that the
service is not automatically starting during boot-up and therefore
no alarm messages are generated.