9.4
CAN Bus Termination
In a CAN bus system, both end modules must be terminated. This is necessary to avoid
transmission errors caused by reflections in the line.
The termination is made by an internal 120 Ω resistor between CAN A (LOW)
and CAN B (HIGH).