ENABLE_H
–
ENABLE_L >= 15V
STO aktivated
Enable (internally)
Software Enable
Speed set point of
the controller
Actual speed
max. 1 s
G-EMRAMP
SS1 aktivated
Timing Diagram
If the ENABLE_L and ENABLE_H are changed from any status to the "Drive Ready" status,
the servo amplifier is not immediately enabled. In addition, in the software (
K-EN
= 1) or the
corresponding bit in the "control word" must be set so that the software "enable" can be set
and the drive therefore switched to the operational mode.