DIAS-DRIVE 210-23
30.03.2021
Page 71
7.6 Additional Information
7.6.1 "Safe Restart" STO (Safe Torque Off)
The DIAS Drive, in combination with the optional VARAN interface, supports the safety
functions SS1 (Safe Stop 1) and STO (Safe Torque Off), and meets the requirements for
Category 4 Performance Level "e" according to EN ISO 13849-1 and SIL3 according to EN
62061.
For his purpose, the servo amplifier has two safe inputs ENABLE_L und ENABLE_H.
The relay output S1/S2 can be used to provide the status of the safety function. It is not
safety-relevant, but can be used to test the external safety function.
The stop brake control is not a component of the safety function. If a safe shutdown of the
stop brake is required, the +24 V-BR brake supply must also be shut down externally.
For the 24 V supply, only PELV/SELV can be used.