DIAS-DRIVE 210-23
30.03.2021
Page 55
17
Host
communica-
tion
─ No new values were
transmitted for two suc-
cessive cycles
─ Internal communication
error with the interface
─ Synchronization is not engaged,
check A-CTIME and the cycle
time of the control
─ Check A-STIME
─ Communication interrupted,
check
─ see also I-DERROR
18
Amplifier error E2
(I-DERROR)
─ Various internal errors
─ see also
I-DERROR
─ Contact manufacturer
19
Amplifier error E1
(I-DERROR)
─ Various internal errors
─ see also
I-DERROR
─ Contact manufacturer
Power output error:
─ Motor cable has a ground
fault
─ The motor has a ground
fault
─ Output stage defective
─ Check motor cable, exchange if
necessary
─ Exchange the motor
─ Exchange amplifier
Ballast circuit error
─ Ballast cable has a ground
fault
─ Ballast resistor has a
ground error
─ Ballast output defective
─ Exchange ballast cable
─ Exchange ballast resistor
─ Exchange amplifier
20
"Enable
locked"
error
─ The amplifier is "enabled"
in the software when one
of safety inputs still has
"low" a signal.
─ Enable amplifier only if ENABLE
and
EN-BRAKE are "high".
21
Driver voltage error
─ The amplifier is "enabled"
in the software when
"Lock" still has a signal.
─ Enable the amplifier only if the
LOCK signal is "high".
22
DC over voltage
and
brake
re-
sistance
limit
reached.
─ Brake resistance power is
insufficient. Brake re-
sistance power has been
reached and the resistor
was deactivated.
─ An external brake resistor must
be used to adjust the value of
G-MBAL
.
23
Brake supply error:
─ Stop brake voltage 24V-
BR missing.
─ Stop brake switch defec-
tive.
─ If the motor has a stop brake,
the amplifier can only be "ena-
bled" when 24V-BR is applied
to the stop brake.
─ Exchange amplifier
24
Reserved
25
I2t error
─ I-I2T has exceeded the
warning value A-I2TERR .
─ Increase A-I2TERR.
26
Motor temperature
warning
─ I-TEMPM has exceeded
the warning value A-
TEMPMW.
─ Increase A-TEMPMW.
Содержание DIAS-DRIVE 210-23
Страница 8: ...DIAS DRIVE 210 23 Page 8 30 03 2021 1 4 Servo Amplifier Components ...
Страница 12: ...DIAS DRIVE 210 23 Page 12 30 03 2021 1 8 Block Diagram ...
Страница 60: ...DIAS DRIVE 210 23 Page 60 30 03 2021 6 3 Dimensions ...
Страница 65: ...DIAS DRIVE 210 23 30 03 2021 Page 65 7 2 Mechanical Dimensions Integrated into the SDD3xx servo amplifier ...
Страница 79: ...DIAS DRIVE 210 23 30 03 2021 Page 79 ...
Страница 81: ...DIAS DRIVE 210 23 30 03 2021 Page 81 ...