DIAS-DRIVE 210-23
Page 52
30.03.2021
5.2.2
Amplifier Malfunctions
Amplifier Malfunctions
Possible Causes:
Solution
─ When the motor is turning
in the clockwise direction
(observe the motor shaft)
I-FPOS is reduced
─ Resolver does not func-
tion correctly
─ Resolver connected
incorrectly
─ Check Resolver
─ Connect Resolver according to
schematic (Page22)
─
Motor does not turn
─
Motor current reaches
limit, however, without
torque
─ Resolver does not func-
tion correctly
─ Resolver connected
incorrectly
─ Check connections on motor
terminal board
U, V, W
─
The Motor "spins
through"
─ The torque is too low or
different in the directions
─ Resolver does not func-
tion correctly
─ Resolver connected
incorrectly
─ Check the
M-ROFF
parameter
─ Check the motor and feedback
connection
─
Motor stops in specified
positions
─ Resolver does not func-
tion correctly
─ Resolver connected
incorrectly
─ Check the
M-POL
and
M-RPOL
parameters corresponding to the
motor data.
─ Exchange the motor ca-
ble(especially with drag chains)
─ Check motor cable connections
─
The motor oscillates
─ Resolver does not func-
tion correctly
─ Resolver connected
incorrectly
─ Reduce V-KP and/or P-KV
─ Check the feedback cable and
exchange it if needed. (Especial-
ly with drag chains)
Содержание DIAS-DRIVE 210-23
Страница 8: ...DIAS DRIVE 210 23 Page 8 30 03 2021 1 4 Servo Amplifier Components ...
Страница 12: ...DIAS DRIVE 210 23 Page 12 30 03 2021 1 8 Block Diagram ...
Страница 60: ...DIAS DRIVE 210 23 Page 60 30 03 2021 6 3 Dimensions ...
Страница 65: ...DIAS DRIVE 210 23 30 03 2021 Page 65 7 2 Mechanical Dimensions Integrated into the SDD3xx servo amplifier ...
Страница 79: ...DIAS DRIVE 210 23 30 03 2021 Page 79 ...
Страница 81: ...DIAS DRIVE 210 23 30 03 2021 Page 81 ...