2.2.10 Stop Brake Control
t
t
t
t
t
t
t
t
Enable
Speed
Setpoint
Host
Speed
Setpoint
internally
Actual
Speed
Enable
internally
Brake
Signal
t
t
Brake
Force
t
t
t
t
Emergency
ramp
t
BRon
t
BRoff
Max. 1 sec
Speed
threshold
Brake
disable
delay
time
Brake
enable
delay
time
t
t
+24V_BR
Min. 0.2 sec
Min. 0.1 sec
The diagram above shows the stop brake function.
A standard stop brake with 24 volts DC and a maximum of 2 Amps can be used on the
servo amplifier.
The circuit has high function reliability, but provides no protection for person-
nel.