1.10 Environmental conditions, Ventilation and Mounting
Storage conditions
Page 50
Transport conditions
Page 50
Operational environmental conditions
0 to +45°C (32 to 113°F) at rated values
+45 to 55°C (113 to 131°F) at power reduction by 2.5% / K
Humidity
Relative humidity 95%, no condensation
Installation altitude above sea level
0-2000 m without derating
> 2000 m with derating of the maximum environmental
temperature by 0.5 °C per 100 m
Pollution degree
2
Overvoltage category
III
Servo amplifier protection class
IP 20
Mounting position
Page 25
Ventilation
Forced ventilation with internal fan controller
1.11 Auxiliary supply voltage
The power supply mounted in the control cabinet, which provides the +24 V auxiliary and
brake voltage (+24V-BR), must output a galvanically isolated protective extra low voltage
(PELV) according to EN60950. Due to the start current of the electrical torque, the rated
current must be at least 5A.