S-DIAS AXIS MODULE
DC 061-1
23.08.2019
Page 33
9
Wiring Examples
In the following sub chapters, wiring examples are provided. It must be ensured that all
constructive measures etc. are complied with and applied in order to fulfill the requirements
of the category used.
9.1
Performance Level e, Category 4 or SILCL 3
– Safety PLC
To meet the requirements of category 4, performance Level "e" for EN ISO 13849-1 and
SILCL 3 according to EN / IEC 62061, two error-proof output of a Safety PLC must be used.
Cross-circuit detection between the two lines via the output tests of the STO 081 is hereby
possible.
Содержание DC 061-1
Страница 15: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 13...
Страница 17: ...S DIAS AXIS MODULE DC 061 1 23 08 2019 Page 15 3 Mechanical Dimensions...
Страница 24: ...DC 061 1 S DIAS AXIS MODULE Page 22 23 08 2019 5 Wiring 5 1 Wiring Example...
Страница 36: ...DC 061 1 S DIAS AXIS MODULE Page 34 23 08 2019...
Страница 38: ...DC 061 1 S DIAS AXIS MODULE Page 36 23 08 2019...
Страница 40: ...DC 061 1 S DIAS AXIS MODULE Page 38 23 08 2019...
Страница 42: ...DC 061 1 S DIAS AXIS MODULE Page 40 23 08 2019...