CCP 521
C-DIAS PROCESSOR MODULE
Page 26
15.03.2016
25
DIAS ERROR
An error has occurred while ac-
cessing a DIAS module.
Possible Causes:
-
An attempt is made to access a
nonexistent DIAS module.
-
DIAS bus error.
Solution:
-
Check the DIAS bus
-
Check the termination resistors.
26
WAIT
The CPU is busy.
27
OP PROG
The operating system is currently
being reprogrammed.
28
OP INSTALLED
The operating system has been
reinstalled.
29
OS TOO LONG
The operating system cannot be
loaded; too little memory.
30
NO OPERATING SYSTEM
Boot loader message.
No operating system found in
RAM.
31
SEARCH FOR OS
The boot loader is searching for
the operating system in RAM.
32
NO DEVICE
33
UNUSED CODE
34
MEM ERROR
The operating system loaded does
not match the hardware configura-
tion.
35
MAX IO
36
MODULE LOAD ERROR
The LASAL Module or project
cannot be loaded.
37
GENERELLER BS-
FEHLER
A general error has occurred while
loading the operating system.
38
APPLMEM ERROR
An error has occurred in the
application memory (user heap).
39
OFFLINE
40
APPL LOAD
41
APPL SAVE