ACCESPOINT WLAN HGW
BWH 011
27.11.2020
Page 27
7
Status and Error Messages
Status and error messages are shown in the status test of the LASAL CLASS software.
Number
Message
Definition
Cause/solution
00
RUN RAM
The user program is currently running in
RAM.
The display is not affected.
Info
01
RUN ROM
The user program stored in the program
memory module was loaded into the
RAM and is currently running.
The display is not affected.
Info
02
RUNTIME
The total time for all cyclic objects ex-
ceeds the maximum time; the time can
be configured using 2 system variables:
-
Runtime: Remaining time
-
SWRuntime: Preset value for runtime
counter
Solution:
-
Optimize the application's cyclic
task.
-
Use higher capacity CPU.
-
Configure setpoint
03
POINTER
Incorrect program pointers were de-
tected before running the user program
Possible Causes:
-
The program memory module is
missing, not programmed or de-
fective.
-
The program in the user program
memory (RAM) is not executa-
ble.
-
The buffer battery has failed.
-
The user program has overwrit-
ten a software error.
Solution:
-
Reprogram the memory module,
if the error reoccurs exchange
the module.
-
Exchange the buffering battery
-
Correct programming error
04
CHKSUM
An invalid checksum was detected before
running the user program.
Cause/solution: s. POINTER