
104
User Manual
4 Real-Time Spectrum Analyzer Mode
This chapter introduces the function keys and menu functions of the front panel under the
Real-Time Spectrum Analyzer Mode.
4.1
Frequency & SPAN
4.1.1
Frequency & Span
Set the frequency-related parameters and functions of the analyzer. The sweep will restart every
time the frequency parameters are modified.
The frequency range of a channel can be expressed by these parameters: Start Frequency,
Center Frequency, Stop Frequency and Span. If any of the parameters change, the others will be
adjusted automatically in order to ensure the coupling relationship among them:
start
stop
span
stop
start
center
f
f
f
)/2
f
(f
f
−
=
+
=
, Where
s p a n
f
is the span.
Command Format
[:SENSe]:FREQuency:CENTer
[:SENSe]:FREQuency:CENTer?
Instruction
Sets the center frequency of the spectrum analyzer.
Gets the center frequency.
Parameter Type
Float, unit: Hz, kHz, MHz, GHz
Parameter Range
2.5kHz~27.9999975 GHz
Return
Float, unit: Hz
Example
:FREQuency:CENTer 0.2 GHz
Command Format
[:SENSe]:FREQuency:STARt
[:SENSe]:FREQuency:STARt?
Instruction
Sets the start frequency of the spectrum analyzer.
Gets the start Frequency.
Parameter Range
0 Hz ~ 27.9999975 GHz
Example
:FREQuency:STARt 100 Hz
Содержание SSA5083A
Страница 1: ...User Manual EN_01A SSA5085A SSA5083A Spectrum Analyzer...
Страница 2: ......
Страница 4: ......
Страница 29: ...User Manual XXV 10 2 TROUBLESHOOTING 225...
Страница 30: ......
Страница 97: ...User Manual 67...
Страница 253: ...User Manual 223 Power SYSTem POWer OFF SYSTem RESTart Buzzer DISPlay WINDow BEEP STATe DISPlay WINDow BEEP VOLUme...
Страница 259: ......