SDS5000XSeries Digital Oscilloscope Service Manual
72/ 90
WWW.SIGLENT.COM
8.4
To Check the Power Supply Module
Disconnect all the external cables and devices from the front and
back panel.
Disconnect the power cord of the oscilloscope.
Remove the rear plastic cover and metal cover following the
instructions in chapter Disassembly Procedures. Note that the power
supply module is on the metal frame and you do not have to remove
the power supply module to check it.
Disconnect power supply cable from the acquisition board and keep
the control signal cable connected.
Reconnect the power cord to the receptacle of the power supply
module. Be cautious when working near the power supply module
without the protective cover, high voltage may exist on the heat sink
and other exposed conductor.
Push the ON/OFF button to power on the power supply module.
Test the power supply and control bus signal listed below with a
multi-meter.
Table 14
Pin assignments of connectors on board
Connector
Pin Number Direction
Designation
J24
(Power
Supply)
1
2
3
4
Input
Input
Input
Input
DC12V
DC12V
GND
GND
J22
1
,
5
NULL
Reserved