SDG7000A Arbitrary Waveform
Generator
EN01A
Quick Start
Страница 1: ...SDG7000A Arbitrary Waveform Generator EN01A Quick Start...
Страница 2: ......
Страница 3: ...o modify or change parts of or all the specifications or pricing policies at company s sole decision Information in this publication replaces all previously corresponding material Any way of copying e...
Страница 4: ...RATION I GENERAL SAFETY SUMMARY 1 SAFETY TERMS AND SYMBOLS 3 MAINTENANCE AND CLEANING 4 FIRST STEPS 5 PREPARATION BEFORE USE 6 THE FRONT PANEL 8 THE REAR PANEL 9 TOUCH SCREEN DISPLAY 10 FRONT PANEL OP...
Страница 5: ...onnecting its input or output terminals Connect the Signal Wire Correctly The potential of the signal wire is equal to the earth so do not connect the signal wire to a high voltage Do not touch the ex...
Страница 6: ...be in an abnormal state You need to view the specific prompt information You can try to restart the setting If the fault information is still in place do not use it for testing Contact the manufactur...
Страница 7: ...to be changed or replaced other than authorized by the manufacturer or agent Safety Terms and Symbols Terms used on the instrument DANGER Indicates an injury or hazard that may immediately happen WARN...
Страница 8: ...onnector When cleaning the LCD be careful not to scratch the transparent protective film 2 Use a soft cloth soaked with water to clean the instrument Please disconnect the power supply For more thorou...
Страница 9: ...ible for any defect damage or failure caused by any of the following a Attempted repairs or installations by personnel other than SIGLENT b Connection to incompatible devices incorrect connection c Fo...
Страница 10: ...nds to tilt the instrument upwards for stable placement as well as easier operation and observation of the instrument Before adjustment After adjustment Connecting to Power Supply The standard power s...
Страница 11: ...to Power on Power off Press and hold the power button on the front panel for two seconds to turn off the device or turn it off through the following steps Utility Shut Down The Power button does not d...
Страница 12: ...band I Q signal CH2 is as Q signal Front Panel Keyboard Includes knobs and keys which are used to quickly call or set some common functions See Front Panel Operation for details USB 2 0 Hosts Power Bu...
Страница 13: ...urst and other functions trigger signal can be output from this port When an external trigger is used a trigger signal is input from the port It can also be output as a synchronization signal with the...
Страница 14: ...the modulation sweep burst setting page Waveform Combine Setting provides schematic diagram and setting of two channel combine Click the switches in the area to switch between channel output alone and...
Страница 15: ...be displayed Click the parameter value area to set the value through the virtual keyboard or front panel keyboard If the parameter value or unit is followed by an icon it means that there are multiple...
Страница 16: ...he clock source The clock source is external but no valid external clock was detected Click this icon to quickly set the clock source The phase mode is Locked Click this icon to quickly set the phase...
Страница 17: ...igital bus is turned on the corresponding button light is on Press the Waveform button to quickly recall the waveform selection menu Press the Utility button to quickly recall the system setup menu Nu...
Страница 18: ...channel output on off When the channel is ON the indicator light above the corresponding BNC connector lights up Press this button for 2 seconds to switch the channel output load between 50 and high i...
Страница 19: ...aking setting sine wave as an example some basic parameters of standard waveform are explained Waveform selection Where you can select the waveform type Amplitude High level setting Offset Low level s...
Страница 20: ...e value Vpp Highlevel Lowlevel Offset Highlevel Lowlevel 2 Common Mode The common mode value of the signal when the signal output is set to differential Phase Delay The phase delay of the signal is me...
Страница 21: ...et 3dB bandwidth of noise adjustable PRBS Bit Rate Period Bit rate Symbol period of PRBS sequence The unit of bit rate is bps and the unit of symbol period UI is second The relationship between the tw...
Страница 22: ...S t a r t Arbitrary Waveform Setting Waveform Preview Sample Rate Frequency setting Amplitude Setting Working Mode setting Waveform data source selection Interpolation Mode setting Sequence setting M...
Страница 23: ...he basic waveform parameter setting is the same as that of sine wave In AWG mode the signal generator adopts TrueArb technology to output the specified waveform sequence point by point according to th...
Страница 24: ...bitrary waveform and its source can come from built in waveform saved waveform or EasyWaveX the number of repetitions of each segment can be set In addition the sequence editor also provides some adva...
Страница 25: ...he software EasyIQ on the host computer which is connected with the instrument through USB or LAN In I Q mode CH1 is used as I channel output and CH2 is used as Q channel output The two outputs share...
Страница 26: ...ter oversampling point Pts Symbol and the conversion relationship Fs Fsymb Pts Symbol Waveform oversampling point information can be obtained in waveform information Waveform Information The waveform...
Страница 27: ...function and open its parameter setting page Modulation type selection Click the modulation type parameter area on the right to select the modulation type Modulation source selection Select the modula...
Страница 28: ...eter setting page Sweep type setting Return to the Home Page Trigger source selection Table 4 Sweep type Sweep type Description Linear Its frequency changes linearly from the starting frequency to the...
Страница 29: ...tting Burst type setting Trigger source selection Burst parameter setting area Quickly switch to carrier parameter setting page Return to the Home Page Table 5 Burst type Burst type Description NCycle...
Страница 30: ...translation requires a special chip the kit needs external USB power supply The kit providing LVDS output directly leads out the LVDS signals without external power supply required Click digital chann...
Страница 31: ...ere When the mode is Totalizer the Totalizer is displayed Current parameter measurement The small font on the right shows the deviation between the measured value and the reference value entered at ex...
Страница 32: ...hs The storage and recalling operations are realized through the file manager as shown in the following figure Address bar Displays the path where the current file list is located This includes some s...
Страница 33: ...ption code see the data sheet for details you will get the option key Follow the instructions below to install the options 1 Utility Options 2 Select the corresponding option name from the option list...
Страница 34: ...illoscope was launched in 2005 SIGLENT has become the fastest growing manufacturer of digital oscilloscopes We firmly believe that today SIGLENT is the best value in electronic test measurement Headqu...