M6048D M12048D
4 Maintenance & Troubleshooting
This troubleshooting guide contains information about how to troubleshoot possible error conditions while
using the M Series Pure Sine Wave Inverter/Charger.
The following chart is designed to help you quickly pinpoint the most common inverter failures.
Code, Indicator and Buzzer
There are two types of alarms: Warning and Fault.
When the warning is triggered, the inverter will still operate until it becomes a “Fault”.
When a fault is triggered, the inverter will shut off and needs to be manually reset to resume operation.
Warning Code
Warning Event
Audible Alarm
Icon flashing
01
MPPT PCB / Inverter Fan
Abnormal
Beep once every second
03
High Battery Voltage
Beep once every second
04
Low Battery Voltage
Beep once every second
07
Overload In Inverter Mode
Beep once every second
12
Solar Charger Over
Temperature
Beep once every second
51
Solar Charger Over Current
Beep once every second