Copyright © Sigicom AB 2020
21
4.1.5.
Factory Default Settings
•
Communication schedule: Each hour
•
Measurement standard: 1A (SS 460 48 66 Spräng, 250mm/s)
•
Threshold: 2.0 mm/s (ON)
•
Interval time: 2 minutes
•
Record time: 4 seconds
•
GPS timesync: Disabled
4.2.
Mounting
Make sure that the C22 is firmly attached and aligned (plumb and level).
For correct measuring results, the mounting angle of the instrument must
not exceed 5º relative to the horizontal plane. Refer to Sigicom product
catalog for more information on mounting solutions.
4.2.1.
Wall Mounting
1.
Tighten all three adjustment screws to their inner position using
an open 8mm wrench.
2.
Identify an even surface where the C22 can be mounted.
3.
Drill for the fastener (e.g. a concrete anchor).
4.
Insert fastener.
5.
Fasten a nut to the head of the bolt.
6.
Attach a washer to the bolt/nut.
7.
Insert the bolt through the center hole of the C22 and screw the
bolt into the anchor (C22 hanging loose).
8.
Hold the C22 against the wall and adjust one or two of the
mounting adjustment screws to ensure all three have full contact
with the wall.
9.
Hold the head of the bolt still with one tool and use an
appropriate tool to tighten the nut to secure the C22 to the wall.
10.
Check that the round plastic cap is inserted into the hole at the
lid to keep water out and prevent ice build-up.
Note! The instrument must not be submerged in water.