EAN-FLIR Cameras
© SightLine Applications, Inc.
8
Hardware connection notes:
•
For the Boson 320 camera, the
camera board is available without the J2 external
camera power connector. In this configuration power to the camera is supplied through the SLA-
3000-FPC board.
•
The 3000-OEM can be configured to accept either the digital or the analog output of the Boson
cameras. SightLine recommends using the digital output from the camera to capture IR
temperature and camera video data.
•
The digital video connection is through the SLA-3000-FPC board. Analog video connection is
through an SMA connector on the SLA-3000-AB board.
•
Reference the
ICD-OEM-Camera Side Interfaces
connecting the video processing boards to the Tau through the FPC interface boards.
•
section for additional connection options.
3000-OEM SLA-3000-IO Serial Port Camera Index
Panel Plus
J1
0/1
NA
J2
VOUT
4
NA
J3
VIN0
2
CAM0/CAM1
J4
VIN1
3
CAM2
Figure 8: 3000-OEM Serial Port and Connector Reference
3.6
4000-OEM Boson Camera Bench Setup
The 4000-OEM can be configured to accept either the digital or the analog output of Boson cameras.
SightLine recommends using the digital output from the camera for full dynamic range (absolute
amplitude) image processing and snapshot recording.
Interface and adapter boards:
•
: Boson camera and SLA-3000-FPC interface.
•
interface. Serial and network interfaces are provided
on the 4000-OEM board (
Figure 9
).
•
The SLA-3000-FPC board can be connected to J6 on the 4000-OEM. Additional camera adapter
boards can be connected using the SLA-4000-MIPI board on J9. See the
for specific MIPI board power requirements.
The 4000-OEM can also be connected directly to the 640 Boson camera through the RHP-BOSON
VPC TTL interface module. See
Cable connections
:
•
SLA-CAB-FPC04: Connects to the 3000-FPC board and the Boson camera with the SLA-FPC-BOSON-E
adapter board. See
•
SLA-CAB-0403: Connects to J4 on 4000-OEM board. Provides an RJ45 Ethernet connection.
•
SLA-CAB-1504: Connects to J50 on the 4000-OEM board and SLA-PWR-B12V-36W power adapter.
•
SLA-PWR-B12V-36W (110-250VAC input / 12VDC output): Connects to J50 on the 4000-OEM board.
J1 - Serial Port 0/1
J2 - Serial Port 4
J4/VIN1 - Serial Port 3
J3/VIN0 - Serial Port 2