EAN-DRS-Cameras
© SightLine Applications, Inc.
6
5.2
Tenum 640 Configuration Notes - 4000-OEM
In the
Acquisition Settings
dialog set
Camera Type
to
Generic Digital
.
The Tenum 640 camera attached to the SLA-4000-4000-MIPI is available as
Cam1
and
Cam 2
.
The
Options
field will set up the onboard FPGA and MIPI clock and call the FPC initialization routine in a
Lua script.
Figure 6: DRS Tenum 640 Camera Configuration
5.3
Tamarisk Camera with Superframe Configuration Notes
•
Superframe is supported in firmware 2.22.15 and later.
•
Data output is 16-bits. There are no programmable ranges.
•
Each 16-bit pixel value represents Kelvin temperature as 11.5 fixed point binary.
•
To get Celsius, use the 16-bit pixel value as the integer, divide by 32.0F, and then subtract 273.15.
5.4
Serial Passthrough
Serial passthrough is supported by the SightLine OEM boards to allow connection to the camera from a
network controlling host. Serial Passthrough for the Tamarisk cameras defaults to:
Baud:
57600
Data Bits:
8
Stop Bits:
1
Parity:
None
When using the DRS camera control GUI with serial passthrough, it may be necessary to unplug any
USB-to-serial adapters plugged into the host PC. The DRS camera control GUI may not be
compatible with these adapters and stop working. Restart the PC after unplugging the devices, and
then run the DRS camera control GUI.
4000-OEM: SightLine was unable to use the DRS camera control software to communicate to the
camera when TCP passthrough was enabled. However, sending direct commands
–
e.g., 01 27 02 00
03 D3 to trigger a flat field correction
–
work as expected.