13
Further Functions Explained
Function key (4)
Implicit parameter menu and parameter adjustment method for import and export
a) Press the function button (18) indicator light “ON” indicates in parameter adjusting mode.
b) Scroll through parameter codes turning knob (14). Codes are shown on meter (3). Once parameter is
selected, adjust the knob (15) with selection shown on the meter (8).
c) Press the function button (18) again, light “OFF” signals exit parameter adjusting mode.
JOB program (5) (6)
In the JOB mode, 100 different JOB records can be stored and recalled. When leaving the factory, has no
saved JOB programs; therefore, operator must first save a program.
Save/Delete the JOB program
• Set JOB mode parameters (welding function, welding mode, welding parameters, etc).
• Press the JOB button (16) and LED will illuminate.
• Select JOB number by the adjustment Knob (15) shown on the digital meter (8).
• Press the Save/Delete button (17) to save the JOB under the selected number.
Recall the JOB program
• Press the JOB button (16) and the JOB LED will illuminate.
• Select the required JOB number by the adjustment Knob (15) as shown on the meter (8).
• Press the JOB button (16) again and the JOB LED is off that signals exit of JOB mode.
DISPLAY
FUNCTION
ADJUSTABLE RANGE
MODE
PrG
PRE GAS
0~5S
PoG
POST GAS
0~10S
SFt
SLOW FEED TIME
0~10
bub
BURN BACK
0~10
SPt
SPOT WELD TIME
0.5~10S
dPC
DELTA PULSE CURRENT
20~200A
DUAL PULSE
FdP
DUAL PULSE FREQUENCY
0.5~3.0Hz
dut
DUAL PULSE DUTY
10~90%
bAL
DUAL PULSE BASE CURRENT ARC
LENGTH
+10/ -10
SCP
START CURRENT PERCENT
10~200%
S4T
SAL
START CURRENT ARC LENGTH
+10/ -10
ECP
END CURRENT PERCENT
10~200%
EAL
END CURRENT ARC LENGTH
+10/ -10
HdC
HYDROCOOLING
ON/OFF
SPG
SPOOL GUN
ON/OFF
Error Type
Error code
Description
Thermal relay
E01
Over-heating (1st thermal relay)
E02
Over-heating (2nd thermal relay)
E09
Over-heating (Program in default)
Welding machine
E10
Phase loss
E11
No water
Communication
E40
Connection problem between wire feeder and power
source
E41
Communication error
Communication
Robot MIG
E51
Communication cord is not connected
E52
Communication cord has problem in connection
E55
Data transaction is interrupted
HSt
HOT START
0~10
MMA
ACF
ARC FORCE
0~10
dSL
DOWN SLOPE
0~10S
TIG