18
Step function
The step function is used for a fast recall of stored preset values.
A step preset includes the following parameters:
-
DC voltage
-
DC current
-
Preset ampere-hour counter set value
-
Pole changer polarity will be shown as plus “+” or minus “-“
character
-
Labeling (step name)
-
Step number
General function:
1.
Status: rectifier is running:
By selecting a step, the preset parameters will be loaded and the
rectifier output will switch directly to the new setpoints. No additional
confirmation is needed!
2.
By selecting a step, the new set values will be shown on the display
for 2 sec. After 2 sec. the display switches to the actual values.
It is not possible to change to “Normal Operation”, or to change from
“Normal Operation” to STEP 1 or to the following, if the ON key was
pressed. There will be a message on the display if you try to do so.
3.
Status: rectifier is not running:
4.
By selecting a step, the preset parameters will be loaded, but the
rectifier will just start after pushing the ON button on the control unit.
The set values of selected step
(except “Normal Operation”) will be
shown continuously until the rectifier will be switch on.