!PATEMP
Return PA temperature information
Return the module’s PA temperature state and current temperature.
Password required:
No
Usage:
•
Query:
AT!PATEMP?
Response:
Temp state: <state>
Temperature: <temperature> degC
OK
Purpose:
Return the module’s Power control temperature information.
Parameters:
<state> (Temperature state):
•
Valid values:
•
"Initializing"
•
"Normal"
•
"High Warning"
•
"High Critical"
<temperature> (Current temperature):
•
Decimal ASCII string
•
Current PA temperature in degrees Celsius. This is the temperature reported by a therm-
istor positioned near the power amplifiers.
•
Example: "32.3"
!PATEMP
(notification)
PA temperature state change—Unsolicited notification
Unsolicited notification received when the PA temperature state changes.
To enable !PATEMP (and other notifications), use AT+WUSLMSK. See
page 127 for details.
Notification format:
!PATEMP: <state>
Parameters:
<state> (PMIC temperature state)
•
Valid range: 1–3
•
1—Normal
•
2—High Warning
•
3—High Critical
Table 3-2: Modem Status Command Details (Continued)
Command
Description