Power Consumption
Figure 40. Typical Hardware Configuration for Power Consumption Measurement
The communication tester is a
CMU 200
from
Rhode & Schwartz
. This tester offers all required
GSM/GPRS
/
EGPRS/CDMA/WCDMA network configurations and allows a wide range of network
configurations to be set.
The
66321D
power supply is used to supply the FX Series, and it could also be used to measure the
total current drain by the device. The current measurement data is read through the GPIB connection.
Rhode & Schwartz NGSM 32/10
is used when measuring with 32V input voltage.
Note that a SIM card must be inserted during all consumption measurements.
The following table lists the recommended equipments to use for the consumption measurement.
Table 70.
List of Recommended Equipments
Device
Manufacturer
Part Number
Notes/Description
Communication Tester
Rhode & Schwartz
CMU 200
Quad Band
GSM/DCS/GPRS/EGPRS/CDMA/
WCDMA
Current measuring power
supply
Agilent
66321D
Used for DC-IN
11.5.1.2.
SIM Cards Used
Consumption measurement may be performed with either 3-Volt or 1.8-Volt SIM cards. However, all
specified consumption values are for a 3-Volt SIM card.
Caution:
The SIM card’s voltage is supplied by the FX Series power supply. Consumption measurement
results may vary depending on the SIM card.
11.5.2. Software Configuration
This section defines the software configuration for the equipment(s) used and the FX Series settings.