OTHER IMPORTANT NOTES -
DURING OPERATION -
If the steamer hose gurgles during use
a. This is a normal result of condensation collecting inside the hose.
Simply lift the control handle upward until the hose is extended to its
full height.
b. The gurgling will disappear when the excess moisture inside the hose
has had a chance to drain back into the base.
If the steamer stops producing steam then starts again
a. You may wish to examine the inside of the reservoir. The most
common reason for this effect is the accumulation of sediment from
mineral laden water.
b. Clean the offending sediment from inside the unit, first following the
steps for cooling and cleaning the unit as presented on a previous
page.
If the steamer indicator ready light does not turn ON and the unit
does not produce steam
There may be an electrical problem with the appliance. Disconnect the
power supply immediately, cool and drain the unit as previously described.
DO NOT use the unit until it has been examined by an qualified repair
technician.
7