5) GAS CONNECTION

The gas connection is located in the rear and on
the right hand underside of these appliances:

24 mm

(

mod

:

ES60GFDBL),

144 mm (mod:ES700GFDBL),
230 mm (mod: ES90WGFDBL).

There are two ways to carry out the connection to
the main gas line:

A. 

The hotplate  can  be  connected  with  rigid  pipe

as specified in AS/NZS 5601.

B. 

If installing with a hose assembly, install with a

hose  assembly  that  complies  with AS/ANZ  1869
(Australian  Certified),  10  mm  ID,  class  B  or  D,  no
more  than  1.2  m  long  and  in  accordance  with
AS/NZS  5601.  Ensure  that  the  hose  does  not
contact  the  hot  surfaces  of  the  hotplate,  oven,
dishwasher  or  any  other  appliance  that  may  be
installed  underneath  or  next  to  the  hotplate.  The
hose should not be subjected to abrasion, kinking
or  permanent  deformation  and  should  be  able  to
be  inspected  along  its  entire  length  with  the
hotplate in the installed position.
Unions  compatible  with  the  hose  fittings  must  be
used and all connections tested for gas leaks.
The  gas  supply  connection  point  must  be
accessible with the appliance installed..

Warning: 

ensure  that  the  hose  assembly  is

restrained  from  accidental  contact  with  the  flue  or
flue outlet of an underbench oven.

Natural Gas

Natural Gas installations require the connection of
a  gas  regulator  at  the  appliance. This  regulator  is
supplied with the appliance on purchase.
Assemble  the  regulator  (noting  the  gas  flow
direction)  and  transition  pieces  (supplied  with  the
appliance), in accordance with figure 7.

The  transition  piece  on  the  supply  side  of  the
regulator must be provided by the installer.

Liquified Petroleum Gas.

In  a  Universal  LP  Gas  installation  the  gas
regulation  is  made  at  the  gas  cylinder  and
regulation  at  the  appliance  is  not  required.  To
connect  supply  to  the  appliance  use  transition
pieces 

as 

shown 

in 

figure  8.  These  pieces  are  supplied  with  the
appliance on purchase.

WARNING:
THE BURNER FLAME MUST BE ADJUSTED BY
THE INSTALLER.
FAULTY  INSTALLATION  WILL  NOT  BE
COVERED UNDER WARRANTY.
THE  APPLIANCE  IS  FACTORY  SET  FOR
NATURAL  GAS.  THE  TEST  POINT  PRESSURE
SHOULD  BE  ADJUSTED  TO  1.00kPa  WITH  THE
WOK BURNER OPERATING AT MAXIMUM.

INSTALLATION

FIG. 7

FIG. 8

Содержание ES60GFDBL

Страница 1: ...ES60GFDBL ES700GFDBL ES90WGFDBL COD 04067IE 17 05 2016 REV00 ...

Страница 2: ...T IN HOTPLATE We ask that you carefully read the instructions within this booklet to enable you to abtain quality results from the outset The appliance must be installed only by an authorised person in compliance with the instructions provided The manufacturer declines all responsability for improper installation which may harm persons and animals and damage property The appliance must be used for...

Страница 3: ...Pan stands support 1F 8 Burner n 2 control knob 9 Burner n 5 control knob 10 Burner n 1 control knob 11 Burner n 3 control knob 12 Burner n 4 control knob Attention this appliance has been manufactured for domestic use only Do not modify this appliance DESCRIPTION OF HOTPLATE To use the WOK pan support on ultra rapid gas burner only if present Put it on the ultra rapid pan support and make sure of...

Страница 4: ...ut situation Never leave the appliance unattended when the burners are being used Make sure there are no children in the near vicinity Particularly make sure that the pan handles are correctly positioned and keep a check on foods requiring oil and grease to cook since these products can easily catch fire The appliance must not be used by people including children with impaired mental or physical c...

Страница 5: ...pliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervised or instruction concerning use of the appliance by a responsible person for their safely Young children should be supervised to ensure that they do not play with the appliance Abnormal Operation Any of the follo...

Страница 6: ...e Customer Care Department Abnormal operations Any of the following are considered to be anormal operation and may require servicing Yellow tipping of the hob burner flame Sooting up of cooking utensils Burners not igniting properly Burners failing to remain alight Burner extinguished by cupboard doors Gas valves which are difficult to turn CAUTION In case of hotplate glass breakage shut immediate...

Страница 7: ...ner head slots T fig 3 have not become clogged by foreign bodies Check that the enamelled burner cap A B C fig 3 3 A has been correctly positioned on the burner head It must be steady The pan support must be placed in the appropriate centering pins verifying the perfect stability Do not force the taps if they are difficult to open or close Contact an Authorised Service Centre for repairs Don t use...

Страница 8: ...e the packaging materials cardboard bags polystyrene foam nails etc within children s reach since they could become potential sources of danger The measurements of the opening made in the top of the modular cabinet and into which the hotplate will be installed are indicated in either fig 4 Always comply with the measurements given for the hole into which the appliance will be recessed see fig 4 4 ...

Страница 9: ...g hooks G fig 6 When the appliance is installed so that the base can be touched we recommend fitting a protecting shield This shield must be at least 70 mm below the base of the bench top fig 4 Timber or other suitable material may be used provided it is capable of withstanding the appliance temperatures Ensure that the supply connection point is accessible with the appliance installed To facilita...

Страница 10: ... leaks The gas supply connection point must be accessible with the appliance installed Warning ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Gas installations require the connection of a gas regulator at the appliance This regulator is supplied with the appliance on purchase Assemble the regulator noting t...

Страница 11: ...onnected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure C taking care of respecting the following correspondences Letter L live brown wire Letter N neutral blue wire Earth symbol green yellow wire The power supply cable must be positioned so that no part of it is able to reach an overtemperature of ...

Страница 12: ...case the appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all gas they are male conical type Reduced rate adjustment Switch on the burner and turn the relative knob to the Reduced rate position small flame fig 1 pag 3 Remove knob M fig 9 and 9 A of the tap which is simply pressed on to...

Страница 13: ...l included in the gas conversion kit 9 NATURAL GAS TO UNIVERSAL LP GAS CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models 1 Remove each burner cap and burner skirt 2 Remove the Natural Gas main injector with a 7 mm VF tube spanner and replace with the appropriate size Universal LP Gas main injector for each burner The following injector sizes are required for Universal LP Ga...

Страница 14: ...his label is supplied in the packet containing the spare injectors The envelope with the injectors and the labels can be included in the kit or at disposal to the authorised Customer Care Department For the sake of convenience the nominal rate chart also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas BURNER ARRANGEMENT ON TH...

Страница 15: ...onductors fig 11 and comply with the recommendations given in paragraph 6 WARNING MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORIZED PERSONS If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n order to avoid a hazard WARNING In the envelope you will find the duplicate parts of the rating plate which must be applied in the cab...

Страница 16: ...e Centre whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from our After Sales Service Centres and a qualified retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations giv...

Отзывы: