![Siemens XQG80-WD14H4602W Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/siemens/xqg80-wd14h4602w/xqg80-wd14h4602w_instruction-manual-and-installation-instructions_385567030.webp)
en
Cleaning and maintenance
30
2.
Turn the programme selector to
Off
.
Pull out the mains plug.
3.
Open the service flap.
4.
Take the drainage hose out of the
holder.
5.
Remove cover flap, drain wash
liquor into a suitable receptacle.
Press on cover flap and insert
drainage hose into the holder.
Note:
Residual water may run out.
6.
Carefully unscrew the pump cover.
Clean the interior, pump cover
thread and pump housing (fan
impeller in the detergent-solution
pump must rotate).
7.
Reinsert and screw on pump cover.
Handle should be vertical.
8.
Close service flap. If required,
engage disengaged service flap
beforehand.
Note:
To prevent unused detergent
from flowing into the outlet during the
next wash: Pour 1 litre of water into
dispenser
II
and start the Spin/
Rinse
programme: (if only a drained cycle is
required: set rpm (spin speed) to
$
).
Drainage hose on the siphon
blocked
1.
Turn the programme selector to
Off
.
Pull out the mains plug.
2.
Loosen hose clip, carefully remove
drainage hose. Residual water may
run out.
3.
Clean drainage hose and siphon
spigot.
4.
Re-attach drainage hose and secure
connection point with hose clip.
Filter in the water inlet hose
blocked
:
Warning
Danger of death from electric shock!!
Do not immerse Aqua-Stop safety
device in water (contains an electric
valve).
First, release water pressure in the
supply hose:
1.
Turn off the tap!
2.
Select any programme (except
Spin/
Rinse
).
3.
Select
Start
/Reload. Leave
programme for approx. 40 s.
4.
Turn the programme selector to
Aus
(Off). Pull out the mains plug.