SECTION 2
Mounting Instructions
(See also VersiCharge Quick Start Guide at usa.siemens.com/versicharge)
2.1 Equipment List
2.1.1 Kit Supplied Equipment
• 1 – VersiCharge (with optional NEMA 6-50 infrastructure plug for 40A Residential Units only)
• 1 – Mounting Bracket
• 1 – Cable Holster
• 1 – Ferrite Core
NOTE:
plug-supplied units (40A) will have the Ferrite core factory installed. Only units to be hardwired (48 A)
will install the Ferrite core.
• 1 – Multi-use Connector (This connector is used to connect both the ModBus and the External Remote Control Interface
Connector.)
NOTE:
Supplied with Commercial Units Only
• RFID Cards: 2 Admin Cards and 5 User cards (Supplied with Commercial Units Only)
• 1 – Tamper resistant 5/32” Allen wrench (for securing the charger)
• 1 – #8 x 2-1/2” Flat Head Drywall Screw (for securing the holster to the wall stud)
• 2 – Lag Screws, Hex Head screws, 1/4 x 2” (for securing the mounting bracket to the wall studs)
• 2 – #10-32 X 3/8”, Tamper Resistant, Pin-In Hex Socket Button Head Cap Screw (for securing the charger).
2.1.2 Standard Installation Equipment:
• Qualified Electrician
• Cordless Drill (Phillips Bit with extender)–include 1/8” drill bit for pilot holes.
• Stud Finder
• 240 V AC Voltmeter
• 40A charger requires a 2-pole, 240V, 50A circuit breaker. 48A charger requires a 2-pole, 240V, 60A circuit breaker.
• NEMA 6-50 Outlet (if not hardwiring charger)
NOTE:
Only
used with the 40A residential charger.
• 7/16” socket wrench
• Flathead Screwdriver
NOTE:
if using the wallboard mounting (alternate mounting) for the charger, a Phillips head screwdriver
will also be needed.
• Tamper resistant 5/32” Hex Bit with ¼” Allen wrench (for securing the charger)
• If hardwiring charger – #6 AWG 90° C copper wire, 3 conductors – #6 AWG 90°C copper wire should be used for 48A charger and
#8 AWG 90° C copper wire should be used for a 40A charger.
NOTE:
1. Wire must have a temperature rating of 90°C or higher. 2. Do not set the amp switch higher than 40A unless hard
wired to a dedicated 60A circuit according to national and local codes.
2.1.3 Alternate Installation Equipment
(screws and anchors are not included in the versicharge kit)
:
• 5 – #12 x 1-½ LG Phillips head Ø.375 head minimum, with 5 – #12 wall anchors (
NOTE:
wall anchors must be rated for 61 lbs.
for 1/2” dry wall ).