TD00.1381.00 13
2 102
Connection plug C (n-system, CAN bus)
Pin Function
Parameter
12 V version
1)
24 V version
Comments
min.
typ.
max. min.
typ.
max.
C2
n-sensor
supply (–)
connected to A6
C3
Term. W
1)
n-sensor signal
input *
Reference potential C2
U
Low to High
[V]
2,8
4
2,8
4
Voltage value at which the
Schmitt trigger input
detects a "low to high" tran-
sition
U
High to Low
[V]
2,3
3,4
2,3
3,4 Voltage value at which the
Schmitt trigger input
detects a "high to low" tran-
sition
U
Hysteresis
[V]
0,4
0,6
0,4
0,6 Hysteresis between "low to
high" and "high to low"
transitions
Current [mA]
- 1,2
- 1,2 at U = - 2 V
Current [mA]
2,7
at U = 14 V
Current [mA]
6,3 at U = 28 V
Frequency [kHz]
5
5
C5
CAN_H
1) 2)
connected
to
A4
C6
CAN_GND
1)
connected
to
A7
C7
CAN_L
1) 2)
connected
to
A8
C8
CAH_H
1)
via R = 120
Ω
connected to
A4, C5
1)
Option
2)
Specification according to ISO 16844-6 (5) and ISO 11898 (6)
The symbol with current data in the "Comments" column indicates
the direction of current.
Содержание VDO DTCO 1381
Страница 4: ...S e r v i c e o n l y IV Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Страница 17: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 1 Product and system overview ...
Страница 33: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 2 Technical data ...
Страница 53: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 3 Operating the DTCO 1381 ...
Страница 74: ...S e r v i c e o n l y 3 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Страница 75: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 4 Data handling ...
Страница 105: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 5 Installation ...
Страница 137: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 6 Installation of the ADR variant ...
Страница 152: ...S e r v i c e o n l y 6 16 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Страница 153: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 7 Preprogramming ...
Страница 161: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 8 Installation and functional test ...
Страница 167: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 9 Activation ...
Страница 179: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 10 First calibration ...
Страница 200: ...S e r v i c e o n l y 10 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Страница 201: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 11 Regularly inspection ...
Страница 222: ...S e r v i c e o n l y 11 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Страница 223: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 12 Maintenance and cleaning ...
Страница 233: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 13 Events and faults ...
Страница 270: ...S e r v i c e o n l y 13 38 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Страница 271: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 14 Appendix ...
Страница 302: ...S e r v i c e o n l y 14 32 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...