UTMC OTU/MOVA Handbook
667/HB/31601/000
Page 64
Issue 5
6.10 UTC OVERRIDE SCREEN
This screen displays the UTC and MOVA control and reply bit values from the controller
interface. The control bits can be overridden to test the interface during commissioning.
Any overrides are automatically deactivated after a timeout which is 5 minutes.
Apply/Reload
This control forces each output to the ‘1’ or ‘0’ state where this has been selected
and then refreshes the screen data values. Any outputs which have not been
forced, i.e. with ‘release’ selected, will remain under control of UTC (or MOVA).
On later versions of firmware (issue 3.0 and above), control outputs which have
been overridden are displayed in
bold
in the table.
Release All
This control sets all overrides back to the ‘release’ state and then refreshes the
screen data values.
:
The WIZ handset command can be used to access a continuously updated
display of the control, reply and detector bits on a port-by-port basis.
To override, select ‘1’
or ‘0’ for each output
then ‘Apply/Reload’