Technical Data
WL Power Circuit Breaker
Ratings for UL 1066 Listed (ANSI C37) Breakers
1) Maintenance means: replacing main contacts and arc chutes (see operating instructions)
M-Class main contacts can be replaced by Siemens personnel only.
2) Short-time Withstand Current I
CW
at 635VAC is 85 kAIC RMS
3) max. 600 V AC
WL frame ratings – Frame size 2
800A
1600A
Rating Class
N
S
H
L
F
N
S
H
L
F
Interrupting current frame Ics (kAIR RMS) 50/60 Hz
254VAC
50
65
85
100
200
50
65
85
100
200
508VAC
50 65 85
100
200
50 65 85 100
200
600VAC
— — —
—
200
— — — —
200
635VAC
50 65 65
85
—
50 65 65
85
—
Short-time current
I
cw (kA RMS)
1 sec.
50
65
65
85
—
50
65
65
85
—
Close and latch rating (kA RMS)
50
65
65
85
—
50
65
65
85
—
Applicable rating plug range
200 - 800A
200 - 1600A
Mechanical
make-time
(ms)
35
35
Mechanical
break-time
(ms)
34
34
Electric close make-time (ms)
50
50
Electric trip/ UV break-time (ms)
40/73
40/73
Electric trip and reclose interval (ms)
80
80
Mechanical duty cycles (no maint.)
15,000
15,000
Electrical duty cycles (no maint)
15,000
15,000
Draw-out breaker efficiency (Watts loss at rated I
n
)
85
320
Draw-out fused breaker efficiency (Watts loss at rated I
n
)
Consult
factory
Consult
factory
Ambient operating temperature (ºC)
-25 to 40
-25 to 40
Weights (Fused Breaker/Breaker/Cradle) lbs.
227/159/112
227/159/112
WL frame ratings – Frame size 2
2000A
3200A
Rating Class
S
H
L
F
S
H
L
Interrupting current frame
I
cs
254VAC
65
85
100
200
65
85
100
(kAIR RMS) 50/60 Hz
508VAC
65
85
100
200
65
85
100
600VAC —
—
—
200
—
—
—
635VAC
65
65
85
—
65
65
85
Short-time current
I
cw (kA RMS)
1 sec.
65
65
85
—
65
65
85
Close and latch rating (kA RMS)
65
65
85
—
65
65
85
Applicable rating plug range
200 - 2000A
200 - 3200A
Mechanical make-time (ms)
35
35
Mechanical break-time (ms)
34
34
Electric close make-time (ms)
50
50
Electric trip/ UV break-time (ms)
40/73
40/73
Electric trip and reclose interval (ms)
80
80
Mechanical duty cycles (no maint.)
15,000
15,000
Electrical duty cycles (no maint)
15,000
15,000
Draw-out breaker efficiency (Watts loss at rated I
n
)
700
1650
Draw-out fused breaker efficiency (Watts loss at rated I
n
)
Consult factory
Consult factory
Ambient operating temperature (ºC)
-25 to 40
-25 to 40
Weights
(Fused
Breaker/Breaker/Cradle)
lbs.
227/209/152
227/209/152
WL frame ratings – Frame size 2
800A
1600A
Rating Class
N
S
H
L
F
N
S
H
L
F
Interrupting current frame Ics (kAIC RMS) 50/60 Hz
254VAC
50
65
85
100
200
50
65
85
100
200
508VAC
50 65 85
100
200
50 65 85 100
200
600VAC
— — —
—
200
— — — —
200
635VAC
50 65 65
85
—
50 65 65
85
—
Short-time current
I
cw (kA RMS)
1 sec.
50
65
65
85
—
50
65
65
85
—
Close and latch rating (kA RMS)
50
65
65
85
—
50
65
65
85
—
Applicable rating plug range
200 - 800A
200 - 1600A
Mechanical
make-time
(ms)
35
35
Mechanical
break-time
(ms)
34
34
Electric close make-time (ms)
50
50
Electric trip/ UV break-time (ms)
40/73
40/73
Electric trip and reclose interval (ms)
80
80
Mechanical duty cycles (with maint.
1
)
15,000
15,000
Electrical duty cycles (with maint.
1
)
15,000
15,000
Draw-out breaker efficiency (Watts loss at rated I
n
)
85
320
Draw-out fused breaker efficiency (Watts loss at rated I
n
)
Consult
factory
Consult
factory
Ambient operating temperature (ºC)
-25 to 40
-25 to 40
Weights (Fused Breaker/Breaker/Cradle) lbs.
227/159/112
227/159/112
WL frame ratings – Frame size 2
2000A
3200A
Rating Class
S
H
L
F
S
H
L
Interrupting current frame
I
cs
254VAC
65
85
100
200
65
85
100
(kAIC RMS) 50/60 Hz
508VAC
65
85
100
200
65
85
100
600VAC —
—
—
200
—
—
—
635VAC
65
65
85
—
65
65
85
Short-time current
I
cw (kA RMS)
1 sec.
65
65
85
—
65
65
85
Close and latch rating (kA RMS)
65
65
85
—
65
65
85
Applicable rating plug range
200 - 2000A
200 - 3200A
Mechanical make-time (ms)
35
35
Mechanical break-time (ms)
34
34
Electric close make-time (ms)
50
50
Electric trip/ UV break-time (ms)
40/73
40/73
Electric trip and reclose interval (ms)
80
80
Mechanical duty cycles (with maint.
1
)
15,000
15,000
Electrical duty cycles (with maint.
1
)
15,000
15,000
Draw-out breaker efficiency (Watts loss at rated I
n
)
700
1650
Draw-out fused breaker efficiency (Watts loss at rated I
n
)
Consult factory
Consult factory
Ambient operating temperature (ºC)
-25 to 40
-25 to 40
Weights
(Fused
Breaker/Breaker/Cradle)
lbs.
227/209/152
227/209/152
Содержание UL 1066
Страница 43: ...6 12 7 Reset reclosing lockout 8 Charge closing spring 9 Switch ON Frame size II Frame size III 9X ...
Страница 56: ...7 5 7 2 Frame size II fused ...
Страница 58: ...7 7 ...
Страница 63: ...7 12 8 27 210 0 8 27 210 0 8 27 210 0 3 75 95 2 ...
Страница 64: ...7 13 ...
Страница 65: ...7 14 7 7 Frame size III fuse carriage ...
Страница 66: ...7 15 ...
Страница 69: ...7 18 7 9 External sensor for neutral conductor WLNCT2 ...
Страница 70: ...7 19 WLNCT3 ...
Страница 85: ...9 5 I tripping Ground fault tripping ...
Страница 231: ...15 12 Pre assembling the locking module Installing 0767 1 2 3 4 6 5 ...
Страница 232: ...15 13 1 Socket head cap screw M5 with washer and nut 7 8 Size 4 5 Nm 45 lb in ...
Страница 271: ...19 10 Function check Then Fit back front panel and side cover on the right if it was removed page 23 4 10 ...
Страница 280: ...21 2 Installing the door sealing frame Not for use with fuse carriages Catalog No Door sealing frame WLDSF 1 2 3 NOTICE ...
Страница 289: ...23 7 23 3 3 Installing arc chutes 1 2 6 5 PH 2 0043 02 3 4 5 6 For frame size III 3 PH 2 ...
Страница 298: ...23 16 6 7 8 9 5 2 1 Size 5 mm ...
Страница 333: ......