Economy increase
The state of the Economy increase (Inactive / Active) can be queried for each
room:
Main menu > Rooms > Room X > Room state > Eco increase:
Setpoint limitation
This operating line shows if setpoint limitation is active in the room (triggered
by the central communication unit via wire bus).
Main menu > Rooms > Room X > Room state > Setpoint limitation:
Apartment timer influence
Define whether or not the apartment timer function of the central apartment
unit (refer to page 28) should act on the selected room.
Main menu > Rooms > Room X > Room settings
> Ap timer influence:
Room
number
1 2 3 4 5 6
Room
name
Factory
setting
Yes Yes Yes Yes Yes Yes
Setting
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Room
number
7 8 9 10
11
12
Room
name
Factory
setting
Yes Yes Yes Yes Yes Yes
Setting
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Optimum start / stop control
Optimum start / stop control brings forward in time changeover of the operat-
ing level against the programmed times, which means that consideration is
given to the house’s thermal dynamics (heating up and cooling down times).
This ensures that the required temperature level is reached at exactly the
programmed time (e.g. at the end of the holiday period).
If that is not the case (too early or too late), a new changeover time is calcu-
lated, which is used on the next day.