Release
1.1
Technical Documentation
11/2005
TD_Repair_L1-L3_SXG75_R1.1.pdf
Page 56 of 61
20 Battery Connector Problems
Fault Symptoms
Customer: GRT:
Mobile does not switch on
No connection to GRT
Battery connector problems
not
okay
Watch for oxidation and
damaged pads of the
battery connector
SCRAP
- has to be send
separately to WSC
Check the status of the
battery connector
visually
Exchange
battery
connector
Continue with
higher repair level
Use the resistor test
function of a multimeter
to check connection
between spring
contacts and soldering
contacts. The value
must be ~ 0
Ω
.
okay
okay
not
okay
- check for twisted or
bent contacts
- check for dry joints
caused by customer
Back to customer
without repair
okay
not
okay
Connector BATTERY
Use hot air blower to remove defective component. Avoid excessive heat! Watch surrounding
components! Resolder new component afterwards.
E-commerce order number: L36334-Z97-C213
E-commerce order name:
CONNECTOR BATTERY 3-POL
Soldering temperature:
~ 360°C TIP Temp.
IRIS Diagnose Code:
13000 Battery/Mechanical Damage
Company Confidential
2005©BenQ